Page 20
Mounting
Wall mounting RTS 1000D
The pressurisation system
RTS 1000D
is designed for wall mounting
For this purpose, 4 mounting links (
2
) are attached to the back of the
equipment.
The wall must be constructed for exposure to dynamic stresses and
strains. LANCIER Monitoring assumes no liability whatsoever for wall
mounting.
The place of mounting should be dry and swept clean.
Minimum distance to adjacent walls and equipment = 100 mm
• Drill 4 holes into a load-bearing wall.
horizontal distance:
525 mm
vertical distance:
830 mm
• Use suitable fastening for the mounting (wall plug and screws).
• Use appropriate lifting tool for a safe positioning of the system.
• Screw the equipment tightly into the 4 holes (
2
) without wall clear-
ance.
Setting up the system RTS 2600D and RTS 5200D
The pressurisation system RTS 2600D und RTS 5200D is
designed to be located at floor level. The floor must be con-
structed for exposure to dynamic stresses and strains. LANCIER
Monitoring assumes no liability whatsoever for wall mounting.
The place of mounting should be dry and swept clean.
Minimum distance to adjacent walls and equipment
= 400 mm
Setting up and connecting backup air storage tank (Option)
• Screw backup air storage tank with suitable fastening for the
mounting (wall plug and screws) to the floor. Mind minimum
distances and access to handhole.
• Connect backup air storage tank with pressurisation system by air hose.
• Check all connections for impermeability.
Remove transportation lock and humidity block
• Remove transportation lock (
16
) from the compressor
(RTS 2600D and RTS 5200D only)
Remove humidity blocks (if provided) from
• condensate discharge hose (
10
) and
• air intake filter (
19
) of the compressor.
RTS 2600D
RTS 5200D
16 19
16
19
Connect the condensate surge tank
• Place the surge tank (
76
) underneath the equipment.
• Guide the condensate discharge hose (
10
) through the desig-
nated opening in the left side panel, insert it on the hose noz-
zle of the condensate surge tank and tighten it with the con-
necting nut.
• The venting holes of the cap must stay open!
76
10
RTS 1000
525 mm
830 mm
2
2
Содержание RTS 1000D
Страница 43: ...Page 43 Compressor VD 7 2 RTS 1000D and VD 28 2 RTS 2600D B...
Страница 45: ...Page 45 Compressor VD 50 4 RTS 5200D...
Страница 57: ...Compressor VD 7 2 and VD 28 2 Page 57...
Страница 59: ...Page 59 Compressor VD 50 4...
Страница 61: ...Page 61 Pneumatics diagram RTS 1000D RTS 2600D and RTS 5200D no 073445 072...
Страница 63: ...Page 63 Circuit and wiring diagram RTS 1000D RTS 2600D und RTS 5200D no 073659 000...
Страница 65: ...Page 65 Circuit and wiring diagram RTS 1000D RTS 2600D und RTS 5200D no 073586 000...
Страница 66: ...Page 66...
Страница 67: ...Page 67...