54
27
•
SELF-DIAGNOSIS AND FAULT IDENTIFICATION
MESSAGES
The main fault warning messages are:
“ Att oFF ”
The appearance of the
[Att OFF]
message indicates
that the steam generator is carrying out the procedures
predefined daily boiler washing.
Wait for the end of the procedure.
“ no GAS ”
No gas. Check
that the shutoff valve is open and that
there is gas coming from the main. If there is no supply
from the main, inform the gas company or agency. If
there is no problem with the main, contact a manufacturer
technician or authorized service agent.
“ Err Fbc - Err Fbb ”
Gas appliances are fitted with ignition devices
incorporating an automatic reset function. If automatic
restore does not take place after several attempts,
displays
7
and
9
will show the error code
[ Err Fbc ]
for
chamber burners or
[ Err Fbb ]
for boiler burners, given in
the margin. An acoustic signal warns the operator. Press
key
15
to restore ignition. If the fault persists, contact a
manufacturer technician or authorized service agent.
Note:
Burner shutdown is a safety condition. Therefore,
this situation is not a sign of the appliance malfunctioning.
If, after carefully carrying out these checks, the
appliance still does not function properly, call a
manufacturer technician or authorized service agent.
Note:
When contacting manufacturer service technicians,
try to explain the fault in as much detail as possible,
referring all the information indicated on the identification
data plate.
WARNING FOR GAS MODELS
“ Err brx ”
Burners Alarm.
Switch the oven off immediately
and call the technical
after-sales service.
Note:
x indicates the number of the burner in alarm
conditions.
90028111rev03