Hydraulic System
273
12.
Connect the pump to the PTO extension shaft. Align the splines on the PTO to those on the
pump for ease of connection.
Figure 5
-
13 Splines on pump
13.
Put all 5/8” bolts back in to secure the pump to the shaft.
14.
Go through Steps 8 to 5 inclusively to reinstall the various components of the pump assembly.
15.
Retighten the breather cap.
16.
Prime the new pump (see
N
OTE
:
Labrie Enviroquip Group strongly recommends you change the filter element and the
hydraulic oil as well as clean the hydraulic tank after installation of a new pump (see
on page 282 and
Caution!
Check level of hydraulic oil in tank. Add oil if needed.