3-3-77
1AH
( 2 ) Adjusting the position of the doctor blade (reference)
Perform the following adjustment if carrier or background appears on the copy image.
Procedure
1. Take the image formation unit out of the machine. (see page 3-3-29)
2. Remove the two screws, and then the upper developing cover.
Screws
Upper developing cover
Figure 3-3-69
3. Insert the thickness gauge into the three point as shown in the arrow, and turning
the three screws to adjust so that the distance between the developing magnet and
the doctor blade is the correct distances: the 0.55mm gauge should go into the gap
and the 0.65 mm one should not.
* The smaller the distance, the lighter the image.
The larger the distance, the darker the image.
Screws
Doctor blade
20mm
Center
Developing roller
20mm
Figure 3-3-70
Содержание DC-2060
Страница 1: ...SERVICE MANUAL Published in Oct 99 841AH110 DC 2060 2560 DC 2060 2560...
Страница 2: ...Service Manual DC 2050 2560...
Страница 4: ......
Страница 13: ...1AH MCE THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section...
Страница 14: ...1AH 1 1 Specifications 1 1 1 Specifications DC 2560 1 1 1 1 1 4 Specifications DC 2060 1 1 4...
Страница 24: ......
Страница 30: ...1AH 1 3 6 1 2 3 4 5 6 7 8 9 0 1 3 3 Drive system Figure 1 3 6 Drive system copier...
Страница 39: ...1AH 1 3 15 Figure 1 3 13 Bypass paper feed section block diagram CN2 10 CN2 14 CN2 13 MPCB BYPSOL BYPCL BYPPSW...
Страница 82: ...1AH MCE ELECTRICAL SECTION II II Electrical Section...
Страница 83: ...1AH 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Страница 84: ......
Страница 94: ......
Страница 105: ......
Страница 124: ...1AH MCE III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 126: ......
Страница 151: ......
Страница 177: ...1AH This page is intentionally left blank...
Страница 185: ...1AH This page is intentionally left blank...
Страница 209: ......
Страница 259: ...3 3 50 1AH Figure 3 3 59 Secondary mirror inclination adjustment screw Secondary mirror...
Страница 262: ...3 3 53 1AH Fourth mirror Fifth mirror Fourth fifth mirror inclination adjustment screw Figure 3 3 62...
Страница 347: ...3 3 132 1AH End Press the stop clear key Exit simulation mode A Remove the paper and reinstall the duplex unit...
Страница 350: ...1AH 3 4 PCB Initial Setting 3 4 1 Replacing the main PCB 3 4 1 3 4 2 Adjustment free variable resistors VR 3 4 4...
Страница 351: ......
Страница 357: ......