If the spreader is to be stored for long periods, it is recommended that the mete-
ring slides are opened, so that the spring tension is not weakened.
If the positioning lever's hydraulic cylinder
fails to completely open
, then the
lever's leaf spring, to which the hydraulic cylinder is attached, can be
unscre-
wed
.
5.8.4.2 Fitting the double acting hydraulic metering slide
control FHD 4 (Optional equipment for MDS 55 / MDS
65 / MDS 85 / 735 M / 935 M)
This hydraulic metering slide control operates with
one double acting
control
valve.
Oil pressure closes - Oil pressure opens
Connecting the hydraulic metering control:
The cylinder for the hydraulic metering slide control FHD 4 is fitted to the right-
hand side of the spreader (when viewed in direction of travel).
Before connecting the hydraulic cylinder to the positioning lever, check that its
assembly length is correct when metering slides are closed and the cylinder is
fully extended.
The cylinder length can be adjusted by releasing the locknut and rotating the
piston fork yoke.
Incorrect fitting
of the hydraulic cylinder can result in
bent positioning
levers
and pins. (See separate assembly information.)
If the positioning lever's hydraulic cylinder
fails to completely open
, the lever's
leaf spring, to which the hydraulic cylinder is attached, can be
unscrewed
.
A