background image

Page  1   

3E4289 Gallagher T11 Reader | Edition 1 | August 2016

 

Copyright © Gallagher Group Limited

Gallagher

 

T11 Reader

Installation Note

T11 Mifare Reader Black: C300410
T11 Mifare Reader White: C300411

T11 Multi Tech Reader Black: C300430
T11 Multi Tech Reader White: C300431

T11 PIV Reader Black: C305410
T11 PIV Reader White: C305411

T11 PIV Reader  - Multi Tech Black: C305430
T11 PIV Reader  - Multi Tech White: C305431

Содержание C300410

Страница 1: ...11 Reader Installation Note T11 Mifare Reader Black C300410 T11 Mifare Reader White C300411 T11 Multi Tech Reader Black C300430 T11 Multi Tech Reader White C300431 T11 PIV Reader Black C305410 T11 PIV...

Страница 2: ...ess and it should not be relied on as such To the extent permitted by law all express or implied or other representations or warranties in relation to the information are expressly excluded Neither Ga...

Страница 3: ...016 Copyright Gallagher Group Limited Contents 1 Introduction 4 2 Before you begin 5 3 Distance between readers 7 4 Installation 8 5 LED indications 10 6 Accessories 10 7 Technical specifications 11 8...

Страница 4: ...IV Reader An HBUS Reader uses the HBUS communications protocol to communicate with the Gallagher Controller A Cardax IV Reader uses the Cardax IV Reader communications protocol to communicate with the...

Страница 5: ...lagher T11 Reader requires a minimum cable size of 4 core 24 AWG 0 2 mm2 stranded security cable This cable allows the transmission of data 2 wires and power 2 wires When using a single cable to carry...

Страница 6: ...evice HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Terminate Remove the on board termination jumper RS485 1 T or Star circuits are not permitted between HBUS devices HBUS Device Termina...

Страница 7: ...es to equivalent wire gauges are only approximate Recommended cable types for optimal HBUS RS485 performance Not applicable for PIV or Gallagher mobile credential reader installations Notes Shielded c...

Страница 8: ...not mounting to a flush box use the reader bezel as a guide to drill all five holes Drill the 13 mm 1 2 inch diameter centre hole this is the centre hole for which the building cable will exit the mou...

Страница 9: ...lack HBUS Termination Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Blue HBUS Reader Positive Red Negative Black HBUS Termination Orange HBUS A Green HBUS B Brown CDXIV TX White CDXIV RX Bl...

Страница 10: ...der is not assigned to a door or elevator car On Green or Red Fully configured and functioning normally Green Access mode is Free Red Access mode is Secure Flashes Green Access has been granted Flashe...

Страница 11: ...70 C Note Direct sunlight may increase the internal reader temperature above the ambient temperature level Humidity 0 95 non condensing3 Environmental protection IP68 Impact rating IK07 Unit dimensio...

Страница 12: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Страница 13: ...her Group Limited 9 Mounting dimensions IMPORTANT This picture is not to scale therefore use the measurements provided 40 mm 1 57 32 mm 1 26 48 mm 1 89 115 mm 4 53 13 mm 1 2 diameter hole for cable 70...

Отзывы: