10. - Maintenance and storage
FC244R / FC244R HD
85
KN330CGB_A
Mower conditioner
10.4 Maintenance
10.4.1 Hydro-pneumatic accumulator
- Before adjusting, maintaining or repairing
the machine, turn off ignition key and wait
until all moving parts have come to a
complete stop.
- Prior to carrying out work on a circuit
comprising a hydro-pneumatic
accumulator, depressurize the circuit.
- It is strictly forbidden to weld, grind or drill
onto a hydro-pneumatic accumulator.
- Regularly check the tightness of the accumulator
fixing bolts and that the hydraulic circuit is leak-free
(a small oil leak can change settings).
- Replace the hydro-pneumatic accumulator
every 10 years.
Check hydro-pneumatic accumulator:
- Conform with the regulations of the country
regarding pressurized equipment.
Hydro-pneumatic accumulator of a capacity
exceeding or equalling 1 L (0.26 US gal).