FC244R / FC244R HD
64
8. - Instructions for work
KN330CGB_A
Mower conditioner
Setting the ground pressure of the mowing
unit
The following adjustments do not cause the
machine to move.
- Place the machine in working position.
- Connect hydraulic hose (1) of the floatation system
to a single acting valve.
- Open the valve using 18 box spanner supplied with
the machine.
- Activate tractor hydraulic spool valve until required
pressure is shown on gauge (2).
1
2
Refer to the decal fitted on the machine.
K9C470TL 0