10. - Maintenance and storage
FC244R / FC244R HD
103
KN330CGB_A
Mower conditioner
Securing elements
- Always replace both knives per disc to avoid
creating an out-of-balance force.
-
The fixing bolts should be changed in the
following cases:
• When there is visible distortion.
•
When the locking compound is worn or
inoperational.
• When the bolt head wear reaches the center line
of the bolt.
• When diameter D of the bolt's body is below 15
mm (0.6’’).
• After having been removed 5 times.
- Replace nuts in the following cases:
• When the contact washer has lost its elasticity.
• When the contact washer loosens itself from the
nut.
• When the nut wear reaches a = 5 mm (0.2’’).
• After having been removed 5 times.
D
a