5 Installation at Site
27 of 132
Amacan P
412.05
112
Fig. 8:
Inserting the O-ring
Refer to and comply with the general arrangement drawing/outline drawing when
installing the pump set.
1. If not already fitted, insert the supplied O-ring 412.05 into pump bowl 112.
2. Attach the crane hook to the bail of the pump set.
3. Centre the pump set above the discharge tube. Slowly lower the pump set into
the discharge tube until it is seated in the recommended position.
(
ð
Section 5.3.1, Page 26)
4. Pull the electric cables up by hand. Fasten them to the sump construction with a
cable support sleeve if required. Do not lift the pump set out of its seat.
X
X
Fig. 9:
Fastening the cable support sleeve
5.3.3 Installation with a support rope
Refer to and comply with the general arrangement drawing/outline drawing when
installing the pump set.
Prior to installing the pump set, visually inspect the support rope. Do not exceed the
permissible load-carrying capacity.
X
59-24
X
59-17.01
Fig. 10:
X = indication of load-carrying capacity
59-24
Support rope
59-17.01
Shackle
CAUTION
Incorrect installation
Damage to the pump set!
▷
Verify that the pump set is correctly seated in the discharge tube.