5 Installation at Site
25 of 132
Amacan P
WARNING
Unintentional starting of the pump set
Risk of injury by moving components and shock currents!
▷
Ensure that the pump set cannot be started unintentionally.
▷
Always make sure the electrical connections are disconnected before carrying
out work on the pump set.
5.3 Lowering the pump set into the discharge tube
DANGER
Improper transport
Danger to life from falling parts!
Damage to the pump set!
▷
Use the attachment point provided for attaching the lifting accessory.
▷
Never suspend the pump set by its power cable.
▷
Use the lifting chain/rope included in the scope of supply exclusively for
lowering or lifting the pump set into/out of the pump sump.
▷
Securely attach the lifting chain/rope to the pump and crane.
▷
Use tested, marked and approved lifting accessories only.
▷
Observe the regional transport regulations.
▷
Observe the product literature supplied by the lifting accessory manufacturer.
▷
The load-carrying capacity of the lifting accessory must be higher than the
weight indicated on the name plate of the pump set to be lifted. Take into
account any additional system components to be lifted.
DANGER
Improper installation in potentially explosive atmospheres
Explosion hazard!
Damage to the pump set!
▷
Comply with the applicable local explosion protection regulations.
▷
Observe the information in the data sheet and on the name plates of pump and
motor.
WARNING
Incorrect handling of the power cable
Personal injury and damage to property!
▷
Secure the power cables against falling down.
▷
Avoid power cables being laid on surfaces without fastening.
▷
When moving the pump set keep at a safe distance from the power cables.
WARNING
People falling into the unsecured discharge tube
Risk of personal injury!
▷
Take suitable precautions during the entire installation/removal process to
protect people from falling into the open discharge tube.
▷
Fence off the work area appropriately.