5 Installation at Site
41 of 132
Amacan P
5.4.2 Electrical connection
DANGER
Electrical connection work by unqualified personnel
Risk of fatal injury due to electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364 and, for explosion-proof models, EN 60079.
WARNING
Incorrect connection to the mains
Damage to the mains network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
CAUTION
Improper routing of power cable
Damage to the power cables!
▷
Never move the power cables at temperatures below - 25
℃
.
▷
Never kink or crush the power cables.
▷
Never lift the pump set by the power cables.
▷
Adjust the length of the power cables to the site requirements.
CAUTION
Motor overload
Damage to the motor!
▷
Protect the motor by a thermal time-lag overload protection device in
accordance with IEC 60947 and local regulations.
For the electrical connection observe the circuit diagrams (
ð
Section 9.3, Page 96)
in the Annex and the information for planning the control system
(
ð
Section 5.4.1, Page 35) .
The pump set is supplied complete with connection cables. Always use all cables
provided and connect all marked cores of the control cable.
DANGER
Incorrect wiring
Explosion hazard!
▷
The connection point of the cable ends must be located outside of the
potentially explosive atmosphere or inside electrical equipment approved to
equipment category II2G.
DANGER
Operating an incompletely connected pump set
Explosion hazard!
Damage to the pump set!
▷
Never start up a pump set with incompletely connected power connection
cables or non-operational monitoring devices.