7 Servicing/Maintenance
61 of 132
Amacan P
WARNING
Pump set tilting or rolling off
Risk of personal injury!
▷
Make sure the pump set is secured against tilting during the entire dismantling
process.
▷
For dismantling the pump set in a horizontal position, secure it against rolling
off.
Observe the general safety instructions and information.
For dismantling and reassembly observe the general assembly drawing.
In the event of damage you can always contact our service departments.
7.5.2 Preparing the pump set
1. De-energise the pump set and secure it against unintentional start-up.
2. Remove the pump set from the discharge tube. (
ð
Section 7.3.1, Page 53)
3. Clean the pump set. (
ð
Section 7.3.2, Page 54)
4. Drain the lubricant. (
ð
Section 7.4.1.4, Page 57) (
ð
Section 7.4.1.4.1, Page 58)
5. Drain the leakage chamber and leave it open for the duration of the
disassembly.
7.5.3 Removing the bellmouth
920.01
138
112
Fig. 31:
Removing the bellmouth
ü
The pump set has been disconnected from the power supply and secured against
unintentional start-up.
ü
The pump set has been placed in a vertical position with the bellmouth on
wooden supports and secured against tipping over.
1. Undo nuts 920.01.
2. Attach the crane hook to the bail and lift the pump set off bellmouth 138.
3. Place the pump set in a horizontal position on wooden supports and make sure
it cannot roll off.