6 Commissioning/Start-up/Shutdown
43 of 132
Amacan P
6 Commissioning/Start-up/Shutdown
6.1 Commissioning/Start-up
6.1.1 Prerequisites for commissioning/start-up
DANGER
Persons in the tank during pump operation
Electric shock!
Risk of injury!
Danger of death from drowning!
▷
Never start up the pump set without special protective equipment when there
are persons in the tank.
▷
If persons come into contact with the fluid handled during pump operation
(e.g. in sports facilities and leisure parks), the plant designer/operator must
comply with the legal requirements.
▷
Provide special electrical and mechanical protective equipment compliant with
the legal regulations.
WARNING
People falling into the unsecured discharge tube
Risk of personal injury!
▷
Take suitable precautions during the entire installation/removal process to
protect people from falling into the open discharge tube.
▷
Fence off the work area appropriately.
Before commissioning/starting up the pump set, make sure that the following
conditions are met:
▪
The lubricant has been checked.
▪
The direction of rotation has been checked.
▪
The pump set has been properly connected to the power supply and is equipped
with all protection devices.
▪
The pump set has been installed in the discharge tube as described in this
manual.
▪
The minimum fluid level has been reached.
▪
After prolonged shutdown of the pump (set), the activities required for returning
the equipment to service have been carried out. (
ð
Section 6.4, Page 48)
▪
Safety-relevant protective equipment must be installed and fully functional.