7 Servicing/Maintenance
68 of 132
Amacan P
7.6.2 Installing the replacement cable gland
412.07
914.04
834.01
412.08
914.05
834.02
812
L
243
L
243
Fig. 39:
Installing the cable gland
Table 21:
Key to the symbols and codes
Symbol
Description
L
243
Always secure screwed connections marked with this symbol with
Loctite 243
.
Connecting the power cable
ü
The motor housing cover has been removed, set down and protected against
rolling off.
1. Adjust the lengths of the cable cores to those of the original cable gland.
2. Attach the core identification to match the original cable gland.
3. Slide O-ring 412.07 onto the core ends of the power cable and into the groove
of the centring seat.
4. Insert cable gland 834.01 with the power cable and O-ring 412.07 into the
opening provided.
5. Fasten cable gland 834.01 with socket head cap screws 914.04 and secure the
screwed connection with Loctite 243.
6. Fasten cable terminals to the core ends.
Connecting the control
cable
ü
The motor housing cover has been removed, set down and protected against
rolling off.
1. Adjust the lengths of the cable cores to those of the original cable gland.
2. Attach the core identification to match the original cable gland.
3. Guide O-ring 412.08 onto the short core ends of the control cable and into the
groove of the centring seat.
4. Insert cable gland 834.02 with the power cable and O-ring 412.08 into the
opening provided.
5. Fasten cable gland 834.02 with socket head cap screws 914.05 and secure the
screwed connection with Loctite 243.