5 Installation at Site
35 of 126
Amacan K
1579.807/07-EN
Table 7:
Symbols key
Symbol
Description
L
243
Always secure screwed connections marked with this symbol with
Loctite 243
.
20. Clamp support 59-7 with clamping element 81-51 to the support rope (f).
21. Undo the screwed connection at clamping element 81-51.
22. Place clamp 81-39 of the clamping element around the support rope.
23. Fasten plate 185 and clamp 81-39 of the GFRP rod to rope clamp 81-39 with
hexagon head bolts 901, discs 550 and cap nuts 920. Tighten the connection and
secure it with Loctite 243. (
NOTE
The support must be firmly clamped to the support rope, and the GFRP rod must be
firmly clamped to the support. If necessary, pad out clamps 81-39.
24. Trim the spacer to fill the space between the two ferrules and accommodate the
support.
25. Guide the power cables and control cable along the support to the next cable
clamp. Pull them taut and secure them with the clamp.
Fig. 22:
Lowering the pump set
26. Progressively lower the pump set into the discharge tube. Secure the cable
bundle with cable clamps.
27. Finally, attach the support rope with shackle and turnbuckle to a suspension
loop (provided in the discharge tube or structure). Secure the turnbuckle with a
split pin. After inserting the split pin, bend over its two legs.
28. Tighten the turnbuckle until the cables are tight but do not lift the pump off its
seat.
29. Unclip the hook of the lifting equipment from the lifting lug, free the electric
cables from the manila rope and route them to the control cabinet.
30. Attach the top loose lifting lug to the cables to prevent noise and wear caused
by chafing.