5 Installation at Site
27 of 126
Amacan K
1579.807/07-EN
WARNING
People falling into the unsecured discharge tube
Risk of personal injury!
▷
Take suitable precautions during the entire installation/removal process to
protect people from falling into the open discharge tube.
▷
Fence off the work area appropriately.
5.3.1 Installing the pump set without support rope
CAUTION
Incorrect installation
Damage to the pump set!
▷
Verify that the pump set is correctly seated in the discharge tube.
101
412.20
Fig. 8:
Inserting the O-ring
Refer to and comply with the general arrangement drawing/outline drawing when
installing the pump set.
1. If O-ring 412.20 is supplied but not fitted, insert it into pump casing 101.
2. Attach the crane hook to the bail of the pump set.
3. Centre the pump set above the discharge tube. Slowly lower the pump set into
the discharge tube until it is seated in the recommended position.
4. Pull the electric cables up by hand. Fasten them to the sump construction with a
cable support sleeve if required. Do not lift the pump set out of its seat.
Fig. 9:
Fastening the cable support sleeve