5 Installation at Site
24 of 126
Amacan K
1579.807/07-EN
WARNING
Incorrect positioning/placing down
Personal injury and damage to property!
▷
Position the pump set vertically with the motor on top.
▷
Use appropriate means to secure the pump set against tilting and tipping over.
▷
Refer to the weights given in the data sheet/on the name plate.
ü
Signs of oil leakage have been detected.
1. Place the pump set in a vertical position.
2. Secure the pump set against tipping over.
3. Remove screw plug 903.03 and joint ring 411.03.
4. Check the lubricant level.
ð
If the lubricant level reaches the opening, fit and tighten screw plug 903.03
with joint ring 411.03 again.
ð
If the lubricant level is below the opening, top up the lubricant.
5. Fit screw plug 903.03 together with a new joint ring 411.03.
903.03
411.03
903.02
411.02
FD
FD
Fig. 7:
Checking the lubricant level
903.03
411.03
Lubricant filler opening
903.02
411.02
Lubricant drain
Table 6:
Symbols key
Symbol
Description
FD
Always apply a
liquid sealant
(e.g. Hylomar SQ32M) to sealing surfaces
marked with this symbol.
NOTE
If more than 1.5 litres of lubricant are required for topping up, this suggests a
defect of the mechanical seals.