5 Installation at Site
39 of 126
Amacan K
1579.807/07-EN
CAUTION
Incorrect wiring
Damage to the sensors!
▷
Observe the limits stated in the following sections of this manual when
connecting the sensors.
The pump set features sensors designed to prevent hazards and damage to the pump
set.
Measuring transducers are required for analysing the sensor signals supplied. Suitable
devices for 230 V AC can be supplied by KSB.
NOTE
Reliable and safe operation of the pump within the scope of our warranty is only
possible if the sensor signals are properly analysed as stipulated in this manual.
All sensors are located inside the pump set and are connected to the sensor cable.
For information on wiring and core marking see (
The individual sensors and the limit values to be set are described in the following
sections.
1
2
3
4
5
6
7
1
8
Fig. 23:
Sensor positions
Position Sensor
Standard
Optional
Motor version
UN
Motor
versions
XN, YN
1
Leakage inside the motor (connection
and winding space)
✘
✘
-
2
Bearing temperature (upper bearing
assembly)
-
-
✘
3
Bearing temperature (lower bearing
assembly)
✘
✘
-