3 Transport/Storage/Disposal
16 of 126
Amacan K
1579.807/07-EN
CAUTION
Damage during storage due to humidity, dirt or vermin
Corrosion/contamination of pump (set)!
▷
For outdoor storage cover the pump (set) and accessories with waterproof
material and protect against condensation.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump!
▷
Clean and cover pump openings and connections as required prior to putting
the pump into storage.
Table 4:
Ambient conditions for storage
Ambient condition
Value
Relative humidity
5 % to 85 % (non-condensing)
Ambient temperature
-20 °C to +70 °C
▪
Store the pump set in dry, vibration-free conditions and, if possible, in its original
packaging.
1. Rotate the impeller by hand once every three months.
2. Spray-coat the inside wall of the pump casing and, in particular, the impeller
clearance areas with a preservative.
NOTE
Observe the manufacturer's instructions for application/removal of the preservative.
3.4 Return to supplier
1. Drain the pump as per operating instructions. (
2. Flush and clean the pump, particularly if it has been used for handling noxious,
explosive, hot or other hazardous fluids.
3. If the pump has handled fluids whose residues could lead to corrosion damage
in the presence of atmospheric humidity or could ignite upon contact with
oxygen, the pump must also be neutralised, and anhydrous inert gas must be
blown through the pump to ensure drying.
4. Always complete and enclose a certificate of decontamination when returning
the pump.
Indicate any safety measures and decontamination measures taken.
(
NOTE
If required, a blank certificate of decontamination can be downloaded from the
following web site: