©Termo-tehnika, d.o.o.
ID.: 17-16-24-3006-03 | 12.2016
35
7.2 Technical data
7.2.1 External device
Device
WPLV-09-S1 NT
WPLV-14-S1 NT
Corresponding hydro module
Mark
HM-141 S1, HM-142 S1
Version
Heat source
External air
Heat sink
Water
Controller
TERMOTRONIC 3000 WEB
Device placement
External
Placement of the controller un.
Internal
Compressor
1 x twin Rotary
Defrosting
Active (change of the cooling circuit direction)
Circulation pump, secondary
/
Capacity
Heating
Heating power / electrical power / COP
2)
A2/W30-35
kW / kW /
-
5,3 / 1,4 / 3,7
9,6 / 2,5 / 3,9
A7/W30-35
kW / kW /
-
5,4 / 1,2 / 4,4
10,6 / 2,1 / 5,1
A-7/W35
kW / kW /
-
5,6 / 2,0 / 2,8
10,9 / 3,7 / 3,0
Cooling
Cooling power / electrical power / EER
3)
A35/W12-7
kW / kW /
-
6,1 / 2,3/ 2,6
12,1 /4,8 / 2,5
Electrical data
External and internal unit
Max. electrical power
9)
kW
9,8
14,2
External unit
Rated voltage
~ 230 V; 50 Hz
3N~ 400 V; 50 Hz
Max. operational current
A
19
11
Max. electrical power
kW
3.2
7,6
Fuses
12)
A
1 x 20
3 x 16
Electrical power cable
4)
mm2
3 x 2,5
5 x 2,5
Refrigerant system
Refrigerant - type
R410A
Refrigerant - quantity
kg
1,9
2,98
Max. operational pressure
MPa
5,0
Cooling (freon) line
Gas
mm
15,88 (5/8'')
Liquid
mm
9,52 (3/8'')
9,52 (3/8'')
Primary side (heat source) - air
Nominal flow
m
3
/h
3,600
7,200
Heating
Range of operation -
min. / max. air temperature
°C
-20 / 40
Cooling
Range of operation -
min. / max. air temperature
°C
20 / 40