4.2.5 Concrete pedestal
The installation (connections above or below ground) routed from the utility room to the device does not
influence the make of the concrete pedestal.
Because of greater safety, installation using an underground cable duct is recommended (installation
V1).
Installation of the concrete pedestal
The reinforced concrete pedestal must be installed on a suitable buffered base. The recommended
minimal edge thickness of the pedestal is 60 mm. Width 1050 mm, depth 420 mm and height 600 mm.
CAUTION
The device must be screwed on the designated places (1) to the concrete pedestal because
of the possibility of stronger gusts of wind.
Legend:
1
Attachment points at the concrete pedestal 2
Attachment points of the device
2