70
Do not cause any short circuits when
carrying out checking, maintenance or
repair work!
12.1.1
Adjusting the Final Pressure
Gauge
If the baling pressure gauge and the pre-selection gauge
overlap each other, the control plate must be set at such
a height that the upper edge of the control plate is
positioned in the middle of the sensor (2), i.e. dimension
b must be half the diameter of the sensor, here 5 mm.
The distance a of the sensor from the control plate must
be 3 mm.
Operational Check
To check its operation, connect the final pressure gauge
to the round baler and the power supply (12 volt). Both
indicator lamps must be illuminated. As soon as the
baling pressure gauges (2) on the left or right hand side
of the machine are raised and exceed the pre-selected
value on the pre-selection gauges, the corresponding
indicator lamps must go out. When both the left and right
hand baling pressure gauges have exceeded the pre-
selected value, a horn signal sounds as well.
Control Sensors
The control sensors (1) on the final pressure gauge are
located on the left and right hand sides of the machine
behind the front protective plates.
KR-0-070
1
2
a
b
KR-0-068
3
2
1
0
1
2
KR-0-069
1