7
WARNING
All stand-off brackets must be attached to fireplace. Do not remove. Top stand-off brackets are not load bearing.
2.6
Appliance Dimensions and Clearances
Table 2.1, Physical Dimensions
Description
Height
Width
Back Width
Depth
Opening
Width
Opening
Height
Top Stand-off
Height
Back to Vent
Center
Inches
32-9/16
50
50
15-13/16
45-7/16
19-7/16
5-3/4
9-15/16
Millimeters
827
1271
1271
402
1154
494
146
252
Table 2.2, Appliance Clearances
Top of appliance stand-offs to framing
0 in.
0 mm
From appliance left side & right side stand-offs
0 in.
0 mm
From appliance back stand-offs
0 in.
0 mm
From bottom stand-offs
0 in.
0 mm
Top of finishing edge to ceiling
36 in.
914 mm
Side of finishing edge to adjacent sidewall
6 in.
152 mm
Appliance front to combustibles
36 in.
914 mm
Mantel projection 9 in. (229 mm) deep from fireplace finishing edge*
14-1/4 in.
362 mm
*Refer to 5.0, Mantel Requirements, on page 12.
Figure 2.1, Slayton 42S Dimensions