36
This function locks the keys to avoid unsupervised operation. A lock icon will
appear on the LCD display screen once activated.
To Activate:
Press the
mode key
and
up key
at same time.
To De-activate:
Press the
mode key
and
up key
at same time.
15.10
Key Lock
Figure 15.7, Key Lock Indicator
15.8
Fan Speed Control
Fan speed can be adjusted through six (6) speeds. A single ‘beep’ will confirm
reception of the command. To activate this function,
1. Press the
mode key
to index to the fan control icon.
2. Press the
up
or
down arrow keys
to turn on, off, or to adjust fan speed.
Thermostat Mode:
Fan(s) have a five (5) minute delay time when fireplace
is lit, allowing time for heat to build in fireplace before operating. The fan will
continue to operate for approximately twelve (12) minutes after fireplace has
been turned off.
Manual Mode:
Fan(s) will operate at previous setting. There is no delay in
start up or stop time.
Figure 15.5, Fan Remote Operation
The light intensity can be adjusted through six (6) levels. A single beep will con-
firm reception of the command.
1. Press the
mode key
to index to
light
icon.
2. Press the
up
or
down arrow keys
to adjust the intensity level.
15.9
Accent Light Kit
Figure 15.6, Accent Light Remote Operation
Remote control battery lifespan depends on various factors including battery
quality, number of ignitions, changes to room thermostat set point, etc.
When the remote control batteries are low, a battery icon will appear on
the LCD display before all battery power is lost.
When batteries are replaced, this icon will disappear.
15.11
Low Battery Detection
Figure 15.8, Low Battery Indicator
The backup battery pack is used when the electrical power to the appliance is interrupted. The lifespan of backup batteries
depends on various factors including battery quality, number of ignitions, changes to room thermostat set point, etc.
When backup batteries are low, a double-beep will be emitted from the IFC control module when it receives an ON/OFF
command from the remote control. This is an alert for a low battery condition of the backup batteries and after this double-
beep warning, no commands will be accepted until batteries are replaced.
When batteries are replaced, a beep will be emitted from IFC control module as soon as powered.
15.11.1
Remote Control
15.11.2
Backup Battery Pack