29
13.0
FIREPLACE SETUP
13.2 Safety Barrier Installation
WARNING
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance
and shall be installed.
NOTE
Please refer to Figure 13.2 for barrier dimensions before installing facing material. The gray, shaded lines represent
the fireplace in relation to the dimensions of the safety barrier
.
All safety barriers require a 1/4 in. (6 mm) minimum top clearance to allow barrier mounting and removal.
WARNING
DO NOT OPERATE THIS FIREPLACE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE GLASS SHALL BE DONE
BY A LICENSED OR QUALIFIED SERVICE PERSON.
1. Remove safety barrier.
2. Remove the valve access cover by backing out one of the (2) hinge screws until the access cover is able to pivot away
from the glass frame.
3. Loosen, but do not remove (2) wing nuts securing component upper heat shield.
4. Remove heat shield.
5. Locate (2) spring loaded handles at bottom of firebox. Pull handles out and down to release.
6. Lift glass frame assembly up and off (2) tabs at top of firebox.
Figure 13.1, Glass Frame Assembly Removal and Installation
Hinge screws securing valve access cover
(1 ea. side)
Wing nuts securing component upper heat
shield
1. Place glass frame assembly top over tabs at top of firebox.
2. Pull bottom handles out and up to secure assembly bottom.
3. Reinstall component upper heat shield, secure with wing nuts.
4. Reinstall valve access cover by securing the hinge screw previously backed out.
5. Reinstall safety barrier.
13.1.2
Install Glass Frame Assembly
13.1.1
Remove Glass Frame Assembly
13.1
Glass Frame Assembly
Handle Location