background image

16 

ATTENTION 

In the USA:  

The appliance may be installed at higher altitudes. Please refer to your American Gas Association 

guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2,000 ft. (610 m) is 
to be reduced 4% for each 1,000 ft. (305 m) above sea level. Refer also to National Fuel Gas Code, ANSI Z223.1 / NFPA 54, 
local authorities, or codes which have jurisdiction in your area regarding the de-rate guidelines. 
 

In Canada:

  When the appliance is installed at elevations above 4,500 ft. (1,372 m), the certified high altitude rating 

shall be reduced at the rate of 4% for each additional 1,000 ft. (305 m). Refer also to CSA-B149.1 Natural Gas and Propane 
Installation Code, Local authorities, or codes which have jurisdiction in your area regarding the de-rate guidelines. 

This fireplace is manufactured for use with Natural Gas. Follow the instructions included with the conversion kit if converting to 
LP gas. (Sold separately) 

ATTENTION 

The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in 
accordance with the requirements of the ANSI Z223.1 installation code. 

CAUTION 

Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any. If not, follow  
ANSI 223.1.   

   

 

Commonwealth of Massachusetts: Installation must be done by a licensed plumber or gas fitter. 

NOTE 

A  listed  (and  Commonwealth  of  Massachusetts  approved)  1/2  in.  (13  mm)  tee  handle  manual  shut-off  valve  and  flexible  gas 
connector are to be connected to the 1/2 in. (13 mm) control valve inlet. If substituting for these components, please consult local 
codes for compliance. 
 
This fireplace is equipped with a 3/8” (10 mm) x 18” (457 mm) long flexible gas connector and manual shut-off valve. The gas line 
should be run to the point of connection where the shut-off valve and flexible gas line will connect. 

 

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing 
of that system at pressures in excess of ½ psi (3.5 kPa). 

 

The  appliance  must  be  isolated  from  the  gas  supply  piping  system  by  closing  its  individual  manual  shut-off  valve  during  any 
pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa). 
 
For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods

IMPORTANT 

The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating conditions 
and was determined independently of any installed system.

 

Table 9.1, Inlet Gas Pressures 

 

Natural Gas 

LP Gas 

Minimum Inlet Gas Pressure 

5” WC (1.25 kPa) [7” WC  (1.74 kPa) (recommended)] 

12” WC  (2.99 kPa) (recommended) 

Maximum Inlet Gas Pressure 

10.5” WC  (2.62 kPa) 

13” WC  (3.24 kPa) 

9.0 

GAS LINE CONNECTION 

9.1 

Gas Conversion 

9.2 

High Altitude Installations 

Содержание Slayton 42S

Страница 1: ...anual with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not proh...

Страница 2: ...e line of gas and wood fireplaces unique cabinets and stylish accessories to complement any d cor Adding a fireplace is one of the best ways to increase the value of your home and we are proud to offe...

Страница 3: ...32 14 0 CONTROL SYSTEM COMPONENTS 33 14 1 Remote Control 33 14 2 Gas Valve 33 14 3 Pilot Assembly 33 15 0 SYSTEM OPERATION 34 15 1 Prepare Components 34 15 2 Initialize the Control System for the Fir...

Страница 4: ...ren and other at risk individuals out of the room and away from hot surfaces Clothing or other flammable material should not be placed on or near the appliance Adequate accessibility clearances for se...

Страница 5: ...of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print no less the one half inc...

Страница 6: ...ower Assembly SL42 HHSS Vent Heat Shield Assembly AL36 DRAM Rock Driftwood Accent Media SL42 500 Driftwood Log Set SL42 RAM Rock Accent Media 970 Heat Duct Kit Heat Duct Kit Natural Gas LP Gas Minimum...

Страница 7: ...f fireplace and all components Refer to 18 0 Finalizing the Installation on page 42 NOTE The qualified installer should follow the procedure best suited for the installation 2 5 Installation Overview...

Страница 8: ...illimeters 827 1271 1271 402 1154 494 146 252 Table 2 2 Appliance Clearances Top of appliance stand offs to framing 0 in 0 mm From appliance left side right side stand offs 0 in 0 mm From appliance ba...

Страница 9: ...ng the secondary stand off heat shield and the top stand off brackets located on the top of the fireplace 2 Form the top stand off brackets as shown then re attach to the fireplace using screws previo...

Страница 10: ...fireplace face Do not bend toward fireplace face 4 Position framing stud against stand off located on the backside of nailing flange Secure with nails or screws NOTE Depending on facing material tabs...

Страница 11: ...ional 970 Heat Duct Kit refer to 12 0 970 Heat Duct Kit on page 26 19 in 483 mm represents the minimum distance from the front of the fireplace to back wall of framing This is the minimum wall depth r...

Страница 12: ...of the fireplace must be level with finished hearth Build the hearth to desired size and height If a hearth extension is desired combustible material may be used Above floor level installations A sol...

Страница 13: ...ption of the header 5 0 MANTEL REQUIREMENTS Figure 5 1 Mantel Projections and Non Combustible Zone NOTE If you plan to mount a television above the fireplace please refer to 7 0 Recess Construction on...

Страница 14: ...fireplace must be installed for every type of venting configuration Refer to 11 5 Vent Heat Shield Assembly Installation on page 21 6 0 TYPICAL INSTALLATION OPTIONS 6 1 Horizontal Installation 6 2 Ve...

Страница 15: ...above a heat source Television location rests solely on the homeowner Hussong Manufacturing shall not be held liable for any adverse effects that may be caused by heat on a TV located near a Kozy Heat...

Страница 16: ...nd this point The glass frame assembly must be removable Non combustible material is required at the top and the sides of the fireplace Figure 8 3 reflects these dimensions Do not secure material to l...

Страница 17: ...allation must be done by a licensed plumber or gas fitter NOTE A listed and Commonwealth of Massachusetts approved 1 2 in 13 mm tee handle manual shut off valve and flexible gas connector are to be co...

Страница 18: ...onents will not function on battery back up power 10 0 WIRING SCHEMATICS Figure 10 1 IFC Control Module Wiring IFC Control Module 1 5 V type AA 1 5 V type AA 1 5 V type AA 1 5 V type AA Flame Sensor S...

Страница 19: ...X X Simpson Dura Vent DV PRO 8 x 5 Direct Vent Systems X X 11 0 VENTING 11 1 Approved Vent Systems 11 2 Restrictor Assembly Installation Slide restrictor into exhaust pipe on top of fireplace with tab...

Страница 20: ...nimum Horizontal Vent Pipe Length Maximum Horizontal Run 9 in 6 in 229 mm 152 mm 9 in 229 mm 12 ft 3 66 m Figure 11 2 NG Min Min Horizontal Venting Stand Offs Brackets 90 Elbow Termination Cap 9 229mm...

Страница 21: ...cal Venting Configurations IMPORTANT The vertical vent heat shield included with this fireplace must be installed for every type of venting application Refer to 11 5 Vent Heat Shield Assembly Installa...

Страница 22: ...the screw holes on the vertical vent heat shield 8 The 1 in 25 mm vent stand off tab will rest on top of the vent pipe providing the required minimum 1 in 25 mm clearance from the vent pipe surface Se...

Страница 23: ...0ft 6 1m Horizontal 20ft 6 1m Vertical Figure 11 10 Natural Gas Combination Venting MAXIMUM 20ft 6 1m Horizontal 20ft 6 1m Vertical Figure 11 11 LP Gas Combination Venting After the first elbow 3 ft 9...

Страница 24: ...Kit E 8 Flex Pipe Collar F 8 Pipe on Fireplace or Extension Kit G 800 WPT 3 Wall Pass Through Thimble Figure 11 12 Assembly and Installation of 800 1 Series 1 Mount the required wall pass through thim...

Страница 25: ...r veranda porch deck or balcony Must be fully opened on a minimum of two sides 12 in 305 mm 12 in 305 mm N Between two horizontal terminations 12 in 305 mm 12 in 305 mm O Between two vertical terminat...

Страница 26: ...12 7 5 2 27 Over 20 12 to 21 12 8 0 2 44 CAUTION This appliance must not be connected to or joined with any chimney flue serving any other appliance Approved Cap Approved vent pipe Roof pitch X 12 Dis...

Страница 27: ...cord 1 Fan housing cover plate 3 Wire nuts 1 Speed control mounting bracket 2 Fan wire connectors 1 Speed Control NOTE A junction box cover and hardware must be purchased to mount the speed control CA...

Страница 28: ...ontrol wires with provided wire nuts Run 110 VAC to fan speed control then from the fan speed control through the romex connector on the register bracket Secure grounding wire to the grounding screw i...

Страница 29: ...ng bracket to the junction box with the 2 screws provided 5 Center the register cover over the fan housing cover plate to install Secure register cover to stud wall with the provided mounting screws 6...

Страница 30: ...king out one of the 2 hinge screws until the access cover is able to pivot away from the glass frame 3 Loosen but do not remove 2 wing nuts securing component upper heat shield 4 Remove heat shield 5...

Страница 31: ...and push back to desired position 3 Lower the screen front until the notched tabs are firmly in position To remove lift up and out of slots Safety barriers are available in various colors See your lo...

Страница 32: ...OTE To avoid damage and prolong the life of halogen bulbs never touch with bare hands Always use a soft cloth when handling 13 3 Light Kit 13 3 1 Install Light Kit Figure 13 3 Screw Location on Burner...

Страница 33: ...r positioning burner venturi over burner orifice align ing burner tube with mounting cradles on control board Re install burner venturi housing 4 Reinstall burner cover aligning holes in cover to corr...

Страница 34: ...ey Transmission Thermostat OFF ON SMART Set Point Temperature Level State Flame ON Fan Lights CPI Mode Key Lock Room Temperature Low Battery Alarm Pilot Igniter Flame Sensor Red boot Black boot Black...

Страница 35: ...ton again The pilot will shut down indicating the remote has taken over The system is now initialized 4 Set the ON OFF rocker switch to ON position to operate fireplace with the remote control SW1 But...

Страница 36: ...screen The remote control can operate as a room thermostat The thermostat can be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The...

Страница 37: ...Press the mode key to index to light icon 2 Press the up or down arrow keys to adjust the intensity level 15 9 Accent Light Kit Figure 15 6 Accent Light Remote Operation Remote control battery lifesp...

Страница 38: ...r ignition the IFC control module will stop sparking for approximately 35 seconds After this wait time the IFC control module will start the second try for ignition by sparking for approximately 60 se...

Страница 39: ...ontrol ON OFF button After approximately 2 seconds press the remote control ON OFF button again The IFC control module will reset and the ignition sequence will start again Reset By Cycling Flame In t...

Страница 40: ...AND DOES NOT AFFECT THE PERFORMANCE OR LONGEVITY OF THE FIREPLACE This appliance is equipped with an ignition device which automatically lights the pilot DO NOT try to light the pilot by hand BEFORE O...

Страница 41: ...urn Gas Off to Appliance and call your service technician or the gas supplier NOTE When the fireplace is initially lit condensation will appear on the glass This is normal in all gas fireplaces and wi...

Страница 42: ...t with all other gas appliances on or at full capacity in the house for proper pressure reading 1 Loosen inlet IN pressure tap screw counter clockwise 2 Attach manometer using a 1 4 in 6 mm I D hose 3...

Страница 43: ...to venturi opening will create dramatic results Adjust at slight increments until desired look is achieved Always burn the fireplace for at least 15 minutes and allow the appliance time to cool befor...

Страница 44: ...o burn for 15 minutes If flames indicate there is excessive draft flickering short flames a restrictor may be necessary If flames indicate insufficient draft lifting or ghosting flames a previously in...

Страница 45: ...upplier No LP in tank Check LP propane tank Refill if necessary Wiring disconnection Use wiring schematic in this manual to determine that all wiring connections are secure and correct Pilot flame not...

Страница 46: ...ss Frame Assembly page 29 Improper vent cap installation Adjust if necessary Vent cap blockage Remove debris if necessary Improper pitch on horizontal venting 1 4 in 6 mm rise per foot is required on...

Страница 47: ...ted from electrical current and cleaned vacuumed every six months The bearings are sealed and require no oiling IMPORTANT ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPE...

Страница 48: ...47 LP Gas Orifice 47 700 596 Pilot Assembly Natural Gas NCK SL42 SP Natural Gas Conversion Kit 700 596 1 Pilot Assembly LP Gas LCK SL42 SP LP Gas Conversion Kit 700 408 Remote Control SL42 035 Burner...

Страница 49: ...cept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s...

Страница 50: ...lf any additional obligation of liability connected with the unit Hussong Manufacturing Co Inc may fully discharge all obligations with respect to this Lifetime Warranty by refunding the wholesale pri...

Отзывы: