37
Manual operation of the control system will only operate the burner on ‘HI.’
1. Put the
ON/OFF switch
in OFF position.
2. Press the
red SW1 button
on IFC control module until the module emits
three (3) beeps and an amber LED is illuminated. This indicates the IFC
control module is ready to synchronize with the remote control.
3. Within five (5) seconds, press the
red SW1 button
on IFC control module
again. The pilot will automatically light.
4. Turn main burner on by pressing
ON/OFF switch
to ON position, turn off
by pressing ON/OFF switch to OFF position. Pilot will remain lit even if
burner is turned off.
Figure 15.10, IFC Control Module
SW1 Button
LEDs
15.13
Reset the System for Manual Operation
This system will execute an automatic turn OFF command within (24) hours of a continued pilot flame ignition. This allows the
system to verify correct safety functions. After turn OFF sequence is completed, the IFC control module will re-execute the
latest command.
15.14
Automatic Safety Restart
First Attempt
Starting from OFF, press remote control
ON button
.
Approximately (4) seconds after ON/OFF button is pushed, the IFC control module will start the spark.
First ignition try will last approximately (60) seconds.
Second Attempt
If there is no flame ignition (rectification) during the first try for ignition, the IFC control module will stop sparking for
approximately (35) seconds.
After this wait time, the IFC control module will start the second try for ignition by sparking for approximately (60) seconds.
If ignition is successful on third ignition attempt, there will be a (60) second delay before the main burner lights.
Third Attempt
If after this third attempt there is still no positive ignition, the IFC control module will go into
LOCK OUT
and the red LED will
blink (3) times in intervals
until the system is reset.
15.15
Control Module Ignition Sequence Information
This system has the option of a continuous (standing) pilot feature. This allows you to change from a spark-to-pilot system to
a standing pilot system during cold weather conditions. By having the pilot on continuously, the firebox will remain warm and a
draft is established in the vent, allowing the main burner to turn on with less air-flow disruption.
To activate Continuous Pilot Ignition mode,
1. With system in
OFF
position, press the
mode key
to index to CPI mode
icon.
2. Press the
up arrow key
to activate CPI.
3. Press the
down arrow key
to return to IPI. A single beep will confirm the
reception of the command.
A snowflake icon will be visible during setup of either IPI or CPI modes.
In IPI mode, the snowflake is not visible on LCD screen.
In CPI mode, the snowflake is visible on LCD screen.
15.12
Continuous Pilot / Intermittent Pilot (CPI/IPI)
Figure 15.9, Pilot Indicator
15.15.1
IFC Control Module Ignition Sequence