14
7.1
Television Positioning Considerations
Mounting a TV above a fireplace has become common practice. With this in mind, we conducted tests to determine possible
surface temperatures reached above the fireplace.
Test results determined surface temperatures did not exceed 150°F (66°C) when the following criterium were met:
4-1/4 in. (108 mm) deep recess constructed above the fireplace. Refer to Figure 7.2, Recess Clearances.
Even though temperature tests were performed, mantel depths, ceiling heights, and other factors will affect surface
temperatures. Thus, we advise you to read the following paragraphs carefully before considering mounting a television above
your fireplace.
Most TV manufacturers specify in their instructions that a TV should not be installed on, near, or above a heat source.
Television location rests solely on the homeowner. Hussong Manufacturing shall not be held liable for any adverse effects that
may be caused by heat on a TV located near a Kozy Heat fireplace.
TV operating temperatures are also affected by wall and mantle construction material. It shall be the customer’s responsibility
to satisfy him or herself that the preferred TV mounting and mantle design will not exceed the listed maximum operating
temperature of their electronic goods.
Table 7.1, Recess Clearances / Non-combustible Zone
Location
Clearance
Fireplace Enclosure Ceiling to Appliance Top
31-3/8 in.
797 mm
Fireplace Enclosure Ceiling to Fireplace
Enclosure Floor
62-1/4 in.
1581 mm
Recess Framing to Venting
1 in.
25 mm
Figure 7.2, Recess Clearances
7.0
RECESS CONSTRUCTION
Figure 7.1, Recess Framing
7.2
Recess Framing and Clearances
62-1/4”
(1581mm)
31-3/8”
(797mm)
4-1/4” (108mm)
Maximum Depth
1” (25mm)
Minimum
Clearance to Venting
Fireplace Enclosure Floor