![kozy heat Slayton 42S Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/kozy-heat/slayton-42s/slayton-42s_installation-and-operation-manual_1999781016.webp)
15
8.0
FACING AND FINISHING
WARNING
Maintain all minimum clearances to combustibles from the fireplace and the vent system.
Combustible Material Allowed
Combustible Material Allowed
No Screws Allowed
Non-Combustible Material Only
Figure 8.3, Minimum Non-Combustible Material Dimensions
This fireplace is designed to accommodate non-combustible facing material up to 1/2 in. (13 mm) thick. Install non-combustible
facing material up to the finishing edge (Figure 8.2) that surrounds the glass frame assembly. Do not apply any material beyond
this point. The glass frame assembly must be removable.
Non-combustible material is required at the top and the sides of the fireplace. Figure 8.3 reflects these dimensions.
Do not secure material to lower cover panel with screws, which may damage control system components. Use a silicone sealant
that has a 300°F (149ºC) continuous exposure rating to secure material in this zone.
It is acceptable to pre-drill holes and to use self-tapping screws to attach non-combustible material to top and sides of fireplace
face. Do not use excessively long screws.
Please refer to 13.2, Safety Barrier Installation, on page 29 for barrier dimensions and facing material requirements.
Figure 8.2, Finishing Edge
Figure 8.1, Finished Opened Dimensions