Safety Information—TIGW1U server
Appendix A: Safety Information
Warning:
Although you may be using this guide or another resource as a reference, before
working with your server product pay close attention to these safety instructions. You
must adhere to the assembly instructions in this guide to ensure and maintain
compliance with existing product certifications and approvals. Use only the described,
regulated components specified in this guide. Use of other products / components will
void the UL listing and other regulatory approvals of the product and will most likely
result in noncompliance with product regulations in the region(s) in which the product
is sold.
A.1
Emissions Disclaimer
To ensure EMC (Electromagnetic Compatibility) compliance with your local regional
rules and regulations, the final configuration of your end system product may require
additional EMC compliance testing. For more information, please contact your local
Kontron representative.
See
Appendix B, “Regulatory and Certification Information”
for product Safety and EMC
regulatory compliance information. This is an FCC (Federal Communications
Commission) Class A device.
A.2
Intended Uses
This product was evaluated as Information Technology Equipment (ITE), which may be
installed in Central Offices, Telecommunication Centers, Network Telecommunication
Facilities, offices, schools, computer rooms, and similar commercial type locations
where The National Electric Code (NEC) applies. The suitability of this product for other
product categories and environments (medical, industrial, telecommunications,
residential, alarm systems, test equipment, etc.), other than an ITE application, may
require further evaluation.
Warning:
Anchor the equipment rack: The equipment rack must be anchored to an unmovable
support to prevent it from falling over when one or more servers are extended in front
of the rack on slides. You must also consider the weight of any other device installed in
the rack. A crush hazard exists should the rack tilt forward which could cause serious
injury.
A.2.1
If AC Power Supplies Are Installed
Mains AC power disconnect: The AC power cord(s) is considered the mains disconnect
for the server and must be readily accessible when installed. If the individual server
power cord(s) will not be readily accessible for disconnection then you must install an
AC power disconnect for the entire rack unit. This main disconnect must be readily
accessible, and it must be labeled as controlling power to the entire rack, not just to
the server(s).
Grounding the rack installation: To avoid the potential for an electrical shock hazard,
you must include a third wire safety ground conductor with the rack installation. If the
server power cord is plugged into an AC outlet that is part of the rack, then you must
Содержание TIGW1U
Страница 1: ...Kontron Carrier Grade Server TIGW1U Product Guide December 2009 Rev 1 3...
Страница 8: ...TIGW1U server Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 16...
Страница 76: ...TIGW1U server Server Utilities Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 76...
Страница 86: ...TIGW1U server Troubleshooting Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 86...
Страница 88: ...TIGW1U server Warranty Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 88...
Страница 104: ...TIGW1U server Getting Help Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 104...