Kontron Carrier Grade Server TIGW1U
December 2009
Product Guide, rev. 1.3
51
Server Installations and Upgrades—TIGW1U server
3.5.1.1
Removing the Optical Device Tray from the Chassis
1. Disconnect the power and data connectors from the interposer board on the back of
the optical drive.
2. Loosen the blue captive thumbscrew on the optical drive tray. (“A” in
Figure 37
)
3. Pull the drive tray out of the chassis. (“B”)
4. If a new drive will not be used to replace the existing one, install the optical drive
filler panel into the drive opening and fasten the two accompanying screws. (“A”
and “B” in
Figure 38
)
Caution:
To ensure proper cooling, the optical drive opening cannot be left empty.
5. Remove the interposer board on the back of the optical drive for use on the new
replacement drive.
Figure 37.
Removing the Optical Device Tray from the Chassis
TS000220
B
A
Figure 38.
Using a Filler Panel in the Optical Drive Tray
A
TS000298
B
Содержание TIGW1U
Страница 1: ...Kontron Carrier Grade Server TIGW1U Product Guide December 2009 Rev 1 3...
Страница 8: ...TIGW1U server Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 16...
Страница 76: ...TIGW1U server Server Utilities Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 76...
Страница 86: ...TIGW1U server Troubleshooting Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 86...
Страница 88: ...TIGW1U server Warranty Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 88...