Kontron Carrier Grade Server TIGW1U
December 2009
Product Guide, rev. 1.3
83
Troubleshooting—TIGW1U server
Make sure you have not exceeded the power budget for the server. Go to
http://
us.kontron.com/support/
for a link to software to check your power budget.
5.5
LED Information
The Intel
®
Server Board S5000PHB server board includes LEDs that can aid in
troubleshooting your system.
Table 8
defines these LEDs with a description of their use.
5.6
BIOS Error Messages
When a recoverable error occurs during the POST, the BIOS displays an error message
describing the problem. See
Table 9
.
Table 8.
LED Definitions
LED Name
Function
Location
Color
Notes
ID
Aid in server
identification from
the back panel
Control panel and
board rear left
corner
Blue
Press ID LED button or user
Server Management
software to turn on the LED.
System fault
Visible fault warning
Control panel and
board rear left
corner
Green or
Amber
Green = No Fault
Green blinking = degraded
Amber = critical error or
non-recoverable
Amber blinking = non-
critical error
ATA drive activity
Control panel
Control panel
Green
Blinking = Activity. No action
required.
Memory fault 1–6
Identify failing
memory module
DIMM end rear of
board
Amber
On = Fault
Diagnostic LEDs.
1–4 (LSB, bit1,
bit2, MSB)
Displays port 80
POST codes
Center back edge
of board
Each LED can
be Off, Green,
Amber, Red
See the POST code table
CPU 1 & 2 Fan
Fault
Identify fan failure
Front center board
Amber
On = Fault
CPU 1 & 2 Fault
Identify processor
failure
1” behind
processor socket
Amber
On = Fault
5v Standby
Identify 5v standby
power on state
Front left board
Amber
On = 5v standby power on
Power LED
Identify the power
state of the system
Control Panel
Green
Off = Power is off (off or S5)
On = Power on or S0)
Slow Blink = Low power
state (S1 – S3)
Table 9.
BIOS Error Messages (Sheet 1 of 2)
Error Message
Explanation
GA20 Error
An error occurred with Gate A20 when switching to protected
mode during the memory test.
Pri Master HDD Error
Pri Slave HDD Error
Sec Master HDD Error
Sec Slave HDD Error
Could not read sector from corresponding drive.
Pri Master Drive - ATAPI Incompatible Pri
Slave Drive - ATAPI Incompatible Sec
Master Drive - ATAPI Incompatible Sec
Slave Drive - ATAPI Incompatible
Corresponding drive is not an ATAPI (Advanced Technology
Attachment Packet Interface) device. Run Setup to make sure
device is selected correctly.
A: Drive Error
No response from diskette drive.
Содержание TIGW1U
Страница 1: ...Kontron Carrier Grade Server TIGW1U Product Guide December 2009 Rev 1 3...
Страница 8: ...TIGW1U server Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 16...
Страница 76: ...TIGW1U server Server Utilities Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 76...
Страница 86: ...TIGW1U server Troubleshooting Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 86...
Страница 88: ...TIGW1U server Warranty Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 88...
Страница 104: ...TIGW1U server Getting Help Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 104...