Server Installations and Upgrades—TIGW1U server
5. Remove the heat sink(s) and processor(s). For instructions, see
Section 3.4.4.2,
“Removing a Processor” on page 38
.
6. Remove the four-fan assembly, including the bracket.
7. Disconnect all cables from the server board.
8. Remove the screws that attach the server board to the chassis. (“A” in
Figure 52
)
9. Tilt the server board and lift it from the chassis. (“B”) Use caution in pulling it out
from beneath the Serial B connector at the rear of the chassis.
3.5.6.2
Installing the Server Board Back into the Chassis
1. Set the replacement board into place (“B” in
Figure 53
), using caution to make sure
that no cables are pinched under the board. Insert the rear edge of the board first,
and line up the I/O ports at the rear of the system.
2. Make sure the standoff locations line up correctly and reinsert the seven screws
removed previously. (“A”)
Figure 52.
Removing the Server Board
TS000209
A
B
Содержание TIGW1U
Страница 1: ...Kontron Carrier Grade Server TIGW1U Product Guide December 2009 Rev 1 3...
Страница 8: ...TIGW1U server Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 16...
Страница 76: ...TIGW1U server Server Utilities Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 76...
Страница 86: ...TIGW1U server Troubleshooting Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 86...
Страница 88: ...TIGW1U server Warranty Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 88...
Страница 104: ...TIGW1U server Getting Help Kontron Carrier Grade Server TIGW1U Product Guide rev 1 3 December 2009 104...