Installation
CP6500-V
Page 3 - 4
© 2005 Kontron Modular Computers GmbH
ID 28945, Rev. 01
P R E L I M I N A R Y
2894
5.01.UG.VC.050304/09095
3
3.2
CP6500-V Initial Installation Procedures
The following procedures are applicable only for the initial installation of the CP6500-V in a sys-
tem. Procedures for standard removal and hot swap operations are found in their respective
chapters.
To perform an initial installation of the CP6500-V in a system proceed as follows:
1. Ensure that the safety requirements indicated Chapter 3.1 are observed.
2. Ensure that the board is properly configured for operation in accordance with application
requirements before installing. For information regarding the configuration of the
CP6500-V refer to Chapter 4. For the installation of CP6500-V specific peripheral devices
and rear I/O devices refer to the appropriate chapters in Chapter 3.
3. To install the CP6500-V perform the following:
1. Ensure that no power is applied to the system before proceeding.
2. Carefully insert the board into the slot designated by the application requirements for
the board until it makes contact with the backplane connectors.
3. Using both ejector handles, engage the board with the backplane. When the ejector
handles are locked, the board is engaged.
4. Fasten the two front panel retaining screws.
5. Connect all external interfacing cables to the board as required.
6. Ensure that the board and all required interfacing cables are properly secured.
4. The CP6500-V is now ready for operation. For operation of the CP6500-V, refer to ap-
propriate CP6500-V specific software, application, and system documentation.
Warning!
Failure to comply with the instruction below may cause damage to the
board or result in improper system operation.
Warning!
Care must be taken when applying the procedures below to ensure that
neither the CP6500-V nor other system boards are physically damaged
by the application of these procedures.
Warning!
When performing the next step,
DO NOT
push the board into the back-
plane connectors. Use the ejector handles to seat the board into the
backplane connectors.
Содержание CP6500-V
Страница 127: ...CP6500 V Setup for AMIBIOS8 MAN EZP 80 07 12 02...
Страница 138: ...6 Chapter 2 Main Setup This page has been intentionally left blank...
Страница 158: ...26 Chapter 3 Advanced BIOS Setup This page has been intentionally left blank...
Страница 182: ...50 Chapter 9 Exit Menu This page has been intentionally left blank...
Страница 184: ...52 Chapter 10 Deleting a Password This page has been intentionally left blank...
Страница 190: ...58 Chapter 11 POST Codes This page has been intentionally left blank...