MAINTENANCE
SERVICE PROCEDURE
253
Air Cleaner Inner Element - Replace
1.
First remove the outer element, and then remove the inner
element.
2.
Cover the air connector side (outlet side) with a clean cloth or
tape.
3.
Clean the air cleaner body interior, then remove the cover
from the air intake port in Step 2.
4.
Install a new inner element to the connector, then tighten the
nut.
NOTICE
The inner element must not be cleaned and used again.
When replacing the outer element, replace the inner element
at the same time.
5.
Set the outer element in position, then lock cover (6) with
hooks (2).
6
2
Top
GL
Evacuator valve
Содержание PW160-7K Series
Страница 2: ......
Страница 3: ...3 FOREWORD ...
Страница 14: ...LOCATIONS OF PLATES TABLE TO ENTER SERIAL NO AND DISTRIBUTOR FOREWORD 14 ...
Страница 20: ...20 ...
Страница 205: ...OPERATION TRANSPORTATION 205 Before moving off lock all machine cover and toolbox doors to prevent accidental opening ...
Страница 222: ...TROUBLESHOOTING OPERATION 222 ...
Страница 223: ...223 MAINTENANCE WARNING Please read and make sure that you understand the safety volume before reading this section ...
Страница 304: ...SERVICE PROCEDURE MAINTENANCE 304 ...
Страница 305: ...305 SPECIFICATIONS ...
Страница 307: ...SPECIFICATIONS SPECIFICATIONS 307 1 PIECE BOOM ...
Страница 308: ...SPECIFICATIONS SPECIFICATIONS 308 2 PIECE BOOM ...
Страница 312: ...SPECIFICATIONS SPECIFICATIONS 312 ...
Страница 354: ...ROTATING ARM OPTIONS ATTACHMENTS 354 ...
Страница 357: ......
Страница 358: ...PW160 7K WHEELED EXCAVATOR Form No UEAM003203 2005 KOMATSU All Rights Reserved Printed in Belgium 10 05 ...