8
1057614-W2-D
INSTALLATION
Installation must be carried out in accordance with these instructions, and
must be conducted by designated, qualified and competent personnel.
1.
The installation must comply with the “Water Supply (Water Fittings) Regulations
or Scottish Byelaws” or any particular regulations and practices, specified by
the local water company or water undertakers.
2.
Before commencing, make sure that the installation conditions comply with
the information given in section: ‘Specifications’. For Type 3 valves, see also
installation conditions in the TMV3 Requirements Manual.
3.
Care must be taken during installation to prevent any risk of injury or damage.
4.
The shower control should be positioned for easy access during use and
maintenance. All routine maintenance procedures can be conducted with the
shower control body in place (except forstrainer and checkvalve access). For
all models, allow a minimum of 80 mm clearance in front of the temperature
control to enable removal of the serviceable parts during maintenance.
5.
The fitting of isolation valves is required as close as is practicable to the water
supply inlets of the thermostatic mixing valve.
6.
The use of supply-line or zone strainers will reduce the need to remove debris
at each shower control point. The recommended minimum mesh aperture
dimension for such strainers is 0.5 mm.
7.
Inlet pressure tappings which allow measurement of the inlet pressures tp
the mixing valve under running conditions are particularly recommended for
healthcare applications with Type 3 valves.
8.
Pipework must be rigidly supported.
9.
Pipework dead-legs should be kept to a minimum. The mixing water outlet piping
should not exceed 2 meters and the overall length from the hot water circuit to
the discharge point should not exceed 5 metres.
10.
Supply pipework layout should be arranged to minimise the effect of other outlet
usage upon the dynamic pressures at the shower control inlets.
11.
Do not use oil-based, non-setting jointing compounds on inlet or outlet
connections.
12.
To eliminate pipe debris it is essential that supply pipes are thoroughly flushed
through before connection to the shower control.
General
Outlet Position/Reversed Inlets
All Rada Exact-3 B shower controls are supplied with inlet connections configured
hot - left
,
cold - right
, and
top outlet
as standard. It is essential that inlet supplies
correspond with the red and blue markings on the Thermostatic cartridge.