13
1057614-W2-D
Installation
-
Panel (16 mm +)
Note!
The mounting bracket can also be mounted to the front face of thicker panels
which will receive a further finishing layer of 2 - 17 mm thickness. If this further finishing
layer is not to be provided, the ends of the mounting bracket must be recessed 2 mm
depth) into the panel face until flush. The mounting bracket must be in the correct
orientation for the building method.
1.
Put the building-in shroud in the correct position on the wall and draw around
it with a pencil. Cut out the hole in the panel.
2.
Using the valve and the building-in shroud as a template, mark and drill 2 fixing
holes to secure the mounting bracket in position. The fixing hole dimensions
must be suitable for the selected securing method, appropriate for the particular
panel material.
3.
Follow previous instructions for wall recess installation.
Note!
The inlets accept rising or falling supplies, on thicker panels this may
require the inlet pipework to be configured with elbows or pipe bends immediately
prior to the inlet connections.
4.
Plaster and tile, or finish as appropriate, up to the panel hole perimeter only, and
to a maximum thickness of 15 mm over the front face of the mounting bracket.
Protect the mixing valve and pipe connections during this process.
5.
Follow previous instructions for wall recess installation. Refer to COMMISSIONING.
Installation - Panel
Figure 3
135 mm
124 mm
12 mm
Panel
12 mm
124 mm
Installation To Panels 2 - 10 mm Thick
Installation To Panels 11 - 15 mm Thick
Panel
135 mm
43 mm
55 mm