Thermostatic Cartridge Removal
Figure 1
Temperature and flow knobs are also available with a short lever.
3 mm A/F Hexago
-
nal Wrench
Locking Screw
Temperature
Knob
Removal Clip
Hub
Thermostatic
Cartridge Assembly
Head Nut
Inlet Port Seals
Foam Seal (Adhesive
Backed)
Cleaning/Renewal of Parts
6.
The interior surface of the shower control body must be clean before refitting
cartridge. If scale or deposition is present, clean (without Thermostatic, flow and
checkvalve cartridges fitted) using a mild proprietary inhibited scale solvent, e.g.
domestic kettle descalent. After descaling, rinse body thoroughly in clean water
before refitting cartridges.
Note!
The body interior must be cleaned carefully and not damaged in any way.
Do not use any abrasive material.
7.
Cartridges may only be cleaned by flushing through under a jet of clean water
to remove lodged particles.
Do not descale
. Cartridges are not serviceable,
and must not be dismantled.
Cartridges cannot be tested individually, service condition should be assessed
as part of the performance check; refer to
Commissioning Checks
.
8.
When renewing the Thermostatic cartridge, retain the removal clip and head
nut off the displaced unit and refit.
9.
Examine all accessible seals for signs of deformation or damage, and renew as
necessary, taking care not to damage seal grooves (a Service Pack is available,
containing all seals and strainer screens that may be necessary for renewal
during maintenance or servicing.
10.
Lightly coat all rubber seals with a
silicone-only based lubricant
to assist
reassembling (see lubricants).