further attempts to start engine until condition is corrected.
NOTE: Do not drop starter or strike starter housing. Doing so can damage starter.
Engines in this series use inertia drive electric starters or retractable starters. Inertia drive electric starters are not
serviceable.
Troubleshooting-Starting Diffi
culties
Condition
Possible Cause
Conclusion
Starter does not energize.
Battery
Check specifi c gravity of battery. If low, recharge or replace
battery as necessary.
Wiring
Check fuse condition.
Clean corroded connections and tighten loose connections.
Replace wires in poor condition and with frayed or broken
insulation.
Starter Switch
or Solenoid
Check switch or relay operation. If starter cranks normally,
replace faulty components.
Starter energizes but turns
slowly.
Battery
Check specifi c gravity of battery. If low, recharge or replace
battery as necessary.
Wiring
Check for corroded connections, poor ground connection.
Transmission
or
Engine
Make sure clutch or transmission is disengaged or placed
in neutral. This is especially important on equipment with
hydrostatic drive. Transmission must be exactly in neutral to
prevent resistance which could keep engine from starting.
Check for seized engine components such as bearings,
connecting rod, and piston.
Electric Starting System Tests
1. Test battery on unit.
a. Connect a DC voltmeter across battery terminals
and read battery voltage (key switch OFF).
b. Turn key switch to start position and read battery
voltage again. Turn switch OFF.
Condition
Conclusion
Voltage less than 12 volts. Charge battery.
Battery voltage should not
fall below 9 volts during
cranking.
If it does, battery may be
faulty or there may be a
short in starting circuit.
Have battery load tested.
If battery passes load test,
check circuitry.
2. Remove electric starter cover panel and check fuse
inside plastic holder. Fuse outside holder is a spare.
Condition
Conclusion
Fuse is blown.
Check for a wiring
problem (bare wire, short
circuit). Correct problem
and replace fuse. Try to
start engine. If it still won’t
start, go to step 3.
3. Disconnect blue relay lead. Be sure transmission is
in neutral and PTO is OFF. Connect one end of a
jumper lead to positive terminal of battery. Connect
other end to terminal of relay.
Condition
Conclusion
Relay engages and starter
begins to crank.
Key switch is faulty, or
there is a wiring problem
to/from key switch. Check
wiring and test key switch
circuits with an ohmmeter.