10  Service

 

 

Under  normal  operating  conditions  and  with 

routine  maintenance,  the  KV5000  Kinematic 
Viscosity  System  should  not  require  service.  Any 
service  problem  can  be  quickly  resolved  by 
contacting  Koehler’s  technical  service  department 
either  by  letter,  phone,  fax,  or  email.  In  order  to 
assure the fastest possible service, please provide 
us with the following information. 

 

Model Number:   

 

 

 

 

Serial Number:   

 

 

 

 

Date of Shipment:   

 

 

 

 

         

11  Storage

 

 

This  laboratory  test  instrument  is  equipped  with 

electrical components. Storage facilities should be 
consistent  with  an  indoor  laboratory  environment. 
This testing equipment should not be subjected to 
extremes of temperature and/or moisture. 

 
This equipment  was shipped from the factory  in 

a  corrugated  cardboard  container.  If  long  term 
storage is anticipated, re-packing the instrument in 
a  water-resistant  container  is  recommended  to 
ensure equipment safety and longevity. 

 

12  Warranty

 

 

We, at Koehler, would like to thank you for your 

equipment  purchase,  which  is  protected  by  the 
following  warranty.  If  within  one  (1)  year  from  the 
date  of  receipt,  but  no  longer  than  fifteen  (15) 
months  from  the  date  of  shipment,  Koehler 
equipment  fails  to  perform  properly  because  of 
defects  in  materials  or  workmanship,  Koehler 
Instrument Company, Inc. will repair or, at its sole 
discretion,  replace  the  equipment  without  charge 
F.O.B. its plant, provided the equipment has been 
properly  installed,  operated,  and  maintained. 
Koehler  Instrument  Company  must  be  advised  in 
writing of the malfunction and authorize the return 
of  the  product  to  the  factory.  The  sole 
responsibility of Koehler Instrument Company and 
the  purchaser’s  exclusive  remedy  for  any  claim 
arising  out  of  the  purchase  of  any  product  is  the 
repair  or  replacement  of  the  product.  In  no  event 
shall  the  cost  of  the  purchaser’s  remedy  exceed 
the  purchase  price,  nor  shall  Koehler  Instrument 
Company  be  liable  for  any  special,  indirect, 
incidental,  consequential,  or  exemplary  damages. 
KOEHLER 

INSTRUMENT 

COMPANY, 

INC. 

DISCLAIMS 

ALL 

OTHER 

WARRANTIES, 

EXPRESSED  OR  IMPLIED,  INCLUDING  ANY 

IMPLIED  WARRANTIES  OF  FITNESS  FOR  A 
PARTICULAR  PURPOSE.  Please  save  the 
shipping carton  in  the event the  equipment needs 
to be returned to the factory for warranty repair. If 
the  carton  is  discarded,  it  will  be  the  purchaser’s 
responsibility  to  provide  an  appropriate  shipping 
carton. 

 

13  Returned Goods Policy

 

 

To  return  products  for  credit  or  replacement, 

please  contact  Koehler  Customer  Service  with 
your  purchase  order  number,  our  packing 
list/invoice number, the item(s) to be returned and 
the  reason  for  the  return.  You  will  be  issued  a 
Returned  Authorization  (RA)  number,  which  must 
be  prominently  displayed  on  the  shipping 
container  when  you  return  the  material  to  our 
plant.  Shipping  containers  without  an  RA  number 
prominently  displayed  with  will  be  returned  to  the 
sender.  Goods  must  be  returned  freight  prepaid. 
Returns will be subject to a restocking charge, the 
application  of  which  will  depend  upon  the 
circumstances  necessitating  the  return.  Some 
returns  cannot  be  authorized,  including  certain 
products  purchased  from  outside  vendors  for  the 
convenience 

of 

the 

customer, 

products 

manufactured  on  special  order,  products  shipped 
from  the  factory  past  ninety  (90)  days,  and 
products  which  have  been  used  or  modified  in 
such  a  way  that  they  cannot  be  returned  to  stock 
for future sale. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание KV5000

Страница 1: ...ia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrument...

Страница 2: ......

Страница 3: ...h the applicable standards set forth in this certification Specifications ASTM D445 ASTM D2532 ASTM D6074 ASTM D6158 IP 71 ISO 3104 DIN 51550 FTM 791 305 NF T 60 100 This unit is tested before it leav...

Страница 4: ......

Страница 5: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 1...

Страница 6: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 2...

Страница 7: ...is given cataloging the items that require separation from the equipment along with basic information on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk e...

Страница 8: ...mum the following substances preparations and components have to be removed from any separately collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent...

Страница 9: ...tion 14 5 1 Bath 14 5 2 Power 15 5 3 Engage the Viscometer in Optical Sensor Assembly 15 5 4 Adjusting the Sensors 17 5 5 Control Panel Operation 18 5 6 Test Procedure 19 6 Safety Features 21 6 1 Over...

Страница 10: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 6 10 Service 27 11 Storage 27 12 Warranty 27 13 Returned Goods Policy 27 Notes 28...

Страница 11: ...range of accurate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests or tec...

Страница 12: ...s Any modification or alteration of this equipment from that of factory specifications is not recommended voids the manufacturer warranty product safety performance specifications and or certification...

Страница 13: ...box and remove packing foam 6 Extract instrument and place on suitable cart for transportation to work area lab bench WARNING Be sure two or more individuals are available for extracting and lifting...

Страница 14: ...quipment WARNING Certain mechanical stresses applied to the tempered glass front panel and inner the inner borosilicate glass jar pose a hazard to personnel Impacts to these during normal operation ca...

Страница 15: ...t This port allows for independent temperature measurement of the bath temperature with a thermometer or a Pt 100 RTD probe for precise temperature measurements and digital temperature controller cali...

Страница 16: ...8 500 C02 OS 500 8 1 600 to 8 000 378 600 C02 OS 600 20 4 000 to 20 000 378 650 C02 OS 650 45 9 000 to 45 000 378 700 C02 OS 700 100 20 000 to 100 000 Ubbelohde Viscometers Ubbelohde viscometers measu...

Страница 17: ...eter holders for use with the KV 5000 The correct holder must be used with the corresponding viscometer tube for proper operation Viscometer Tube Type Corresponding Holder Cannon Fenske Routine K23381...

Страница 18: ...ol to learn the heating parameters needed for any particular set point temperature This operation should be done when installing a new unit after replacing or changing the bath medium type or utilizin...

Страница 19: ...or volatilize producing flammable vapors below the maximum instrument operating temperature 25 C NOTE Coloration of the Mineral or Silicon Bath Oil is an indication that the Medium must be changed Se...

Страница 20: ...e Figure 8 Viscometer Tube Completely Inserted in the Optical Sensor Assembly Optical wires are not shown for illustrative purposes only If the optical sensor assembly has a Teflon retaining ring rath...

Страница 21: ...d the receiver When the signal can pass between the two sensors the upper orange light will be on When the signal is interrupted when a meniscus passes through the orange light will flicker or turn of...

Страница 22: ...he viscometer parameters displayed 4 Test Data Displays the run time during a test in seconds Time 1 indicates the elapsed time for a standard test for a viscometer with a single constant The Time 2 i...

Страница 23: ...test procedure listed in section 1 2 of this document when performing Kinematic viscosity testing After the main power switch to the instrument is turned on the control panel will illuminate and disp...

Страница 24: ...n The status will automatically change from RUN to RUN 2 Once the sample passes the second indicator line on the viscometer tube the TIME 2 will automatically stop the status will change from RUN 2 to...

Страница 25: ...s providing proper and adequate voltage Check if Overpower Protection circuitry located directly behind the temperature controller inside the front tray has been activated Check if line switch is in t...

Страница 26: ...ose of this material and its container to a hazardous of special waste collection point Country State or local laws may impose additional regulatory requirements regarding disposal Dispose in accordan...

Страница 27: ...from the main instrument it is now easy to access the inside of the bath jar for further cleaning 16 With the top assembly resting on its back it is now possible to clean the heating coils stirrer bl...

Страница 28: ...low Blow Fuse 0 25A 5x20 mm 278 003 001 Slow Blow Fuse 3 15A 5x20mm 278 020 004 Time Delay Fuse 20A 600VAC 278 102 003 Fast Acting Fuse 0 5A 2AG 275 103 044 Temperature Controller 100 240V with RS 232...

Страница 29: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 25 9 Wiring Diagrams 9 1 Unit Wiring...

Страница 30: ...t for Amp 3 3 Brown 9 9 Blue Y3 V White 10 10 Blue Black X6 Output for Amp1 White 11 11 Blue White X7 Output for Amp 2 White 12 12 Blue Red X10 Output for Amp 3 4 Brown 13 13 White Y4 V White 14 14 Wh...

Страница 31: ...f the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or replac...

Страница 32: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 28 Notes...

Страница 33: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 29 Notes...

Страница 34: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 30 Notes...

Отзывы: