Koehler KV5000 Скачать руководство пользователя страница 11

KV5000 Instrument & Software 

Operation and Instruction Manual 

 

KV5000-Manual

    

 

-

7-

 

1  Introduction 

 

The  Koehler  KV5000  Kinematic  Viscosity 

Instrument  and  Data  Acquisition  Software  is  the 
latest  design  for  performing  kinematic  viscosity 
tests with glass capillary viscometers according to 
the  ASTM  D445  test  method  and  related  test 
specifications. 
 

This  manual  provides  important  information 

regarding  safety,  technical  reference,  installation 
requirements,  operating  condition  specifications, 
user  facility  resource  requirements,  and  operating 
instructions for the Kinematic Viscosity Instrument 
and  Data  Acquisition  Software.  This  manual 
should also be used in conjunction with applicable 
published  laboratory  procedures.  Information  on 
these procedures is given in section 1.2. 

 

1.1 

Koehler’s 

Commitment 

to 

Our 

Customers 

 

Providing  quality  testing  instrumentation  and 

technical support services for research and testing 
laboratories  has  been  our  specialty  for  more  than 
50  years.  At  Koehler,  the  primary  focus  of  our 
business  is  providing  you  with  the  full  support  of 
your  laboratory  testing  needs.  Our  products  are 
backed  by  our  staff  of  technically  knowledgeable, 
trained  specialists  who  are  experienced  in  both 
petroleum products testing and instrument service 
to  better  understand  your  requirements  and 
provide  you  with  the  best  solutions.  You  can 
depend on Koehler for a full range of accurate and 
reliable instrumentation as well as support for your 
laboratory  testing  programs.  Please  do  not 
hesitate  to  contact  us  at  any  time  with  your 
inquiries  about  equipment,  tests,  or  technical 
support. 

 

Toll Free: 1-800-878-9070 (US only) 
Tel: +1 631 589 3800 
Fax: +1 631 589 3815 
 
Email: [email protected] 
http://www.koehlerinstrument.com 

 

1.2  Recommended 

Resources 

and 

Publications 

 

1.  American  Society  for  Testing  and  Materials 

(ASTM) 
100 Barr Harbor Drive 
West  Conshohocken,  Pennsylvania  19428-
2959, USA 
Tel: +1 610 832 9500  
Fax: +1 610 832 9555 

http://www.astm.org

 

email: [email protected] 

 

ASTM Publication: 

 

ASTM  D445:  Kinematic  Viscosity  of 
Transparent and Opaque Liquids (and the 
Calculation of Dynamic Viscosity) 

 

ASTM  D2170:  Kinematic  Viscosity  of 
Asphalts (Bitumens) 

 

ASTM 

D6074: 

Standard 

Guide 

for 

Characterizing 

Hydrocarbon 

Lubricant 

Base Oils 

 

ASTM  D6158:  Standard  Specification  for 
Mineral Hydraulic Oils 

 
2.  International  Organization  for  Standardization 

(ISO) 
1, rue de Varembé 
Case postale 56 
CH-1211 Geneva 20, Switzerland 
Tel: 41 22 749 01 11  
Fax: 41 22 733 34 30 
http://www.iso.org 

 

ISO Publication: 

 

ISO 

3104: 

Petroleum 

products 

– 

Transparent 

and  opaque  liquids 

– 

Determination  of  kinematic  viscosity  and 
calculation of dynamic viscosity 

 
3.  Energy Institute (IP) 

61 New Cavendish Street 
London, WIM 8AR, United Kingdom 
Tel: 44 (0)20 7467 7100  
Fax: 44 (0)20 7255 1472 
http://www.energyinstpubs.org.uk/ 

 

IP Publication: 

 

IP  71:  Kinematic  viscosity  and  calculation 
of dynamic viscosity 

 

IP 319: Kinematic viscosity of bitumens 

 

4.  Deutsche International Norm (DIN) 

http://www.din.de 

 

DIN Publication: 

Содержание KV5000

Страница 1: ...ia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrument...

Страница 2: ......

Страница 3: ...h the applicable standards set forth in this certification Specifications ASTM D445 ASTM D2532 ASTM D6074 ASTM D6158 IP 71 ISO 3104 DIN 51550 FTM 791 305 NF T 60 100 This unit is tested before it leav...

Страница 4: ......

Страница 5: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 1...

Страница 6: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 2...

Страница 7: ...is given cataloging the items that require separation from the equipment along with basic information on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk e...

Страница 8: ...mum the following substances preparations and components have to be removed from any separately collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent...

Страница 9: ...tion 14 5 1 Bath 14 5 2 Power 15 5 3 Engage the Viscometer in Optical Sensor Assembly 15 5 4 Adjusting the Sensors 17 5 5 Control Panel Operation 18 5 6 Test Procedure 19 6 Safety Features 21 6 1 Over...

Страница 10: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 6 10 Service 27 11 Storage 27 12 Warranty 27 13 Returned Goods Policy 27 Notes 28...

Страница 11: ...range of accurate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests or tec...

Страница 12: ...s Any modification or alteration of this equipment from that of factory specifications is not recommended voids the manufacturer warranty product safety performance specifications and or certification...

Страница 13: ...box and remove packing foam 6 Extract instrument and place on suitable cart for transportation to work area lab bench WARNING Be sure two or more individuals are available for extracting and lifting...

Страница 14: ...quipment WARNING Certain mechanical stresses applied to the tempered glass front panel and inner the inner borosilicate glass jar pose a hazard to personnel Impacts to these during normal operation ca...

Страница 15: ...t This port allows for independent temperature measurement of the bath temperature with a thermometer or a Pt 100 RTD probe for precise temperature measurements and digital temperature controller cali...

Страница 16: ...8 500 C02 OS 500 8 1 600 to 8 000 378 600 C02 OS 600 20 4 000 to 20 000 378 650 C02 OS 650 45 9 000 to 45 000 378 700 C02 OS 700 100 20 000 to 100 000 Ubbelohde Viscometers Ubbelohde viscometers measu...

Страница 17: ...eter holders for use with the KV 5000 The correct holder must be used with the corresponding viscometer tube for proper operation Viscometer Tube Type Corresponding Holder Cannon Fenske Routine K23381...

Страница 18: ...ol to learn the heating parameters needed for any particular set point temperature This operation should be done when installing a new unit after replacing or changing the bath medium type or utilizin...

Страница 19: ...or volatilize producing flammable vapors below the maximum instrument operating temperature 25 C NOTE Coloration of the Mineral or Silicon Bath Oil is an indication that the Medium must be changed Se...

Страница 20: ...e Figure 8 Viscometer Tube Completely Inserted in the Optical Sensor Assembly Optical wires are not shown for illustrative purposes only If the optical sensor assembly has a Teflon retaining ring rath...

Страница 21: ...d the receiver When the signal can pass between the two sensors the upper orange light will be on When the signal is interrupted when a meniscus passes through the orange light will flicker or turn of...

Страница 22: ...he viscometer parameters displayed 4 Test Data Displays the run time during a test in seconds Time 1 indicates the elapsed time for a standard test for a viscometer with a single constant The Time 2 i...

Страница 23: ...test procedure listed in section 1 2 of this document when performing Kinematic viscosity testing After the main power switch to the instrument is turned on the control panel will illuminate and disp...

Страница 24: ...n The status will automatically change from RUN to RUN 2 Once the sample passes the second indicator line on the viscometer tube the TIME 2 will automatically stop the status will change from RUN 2 to...

Страница 25: ...s providing proper and adequate voltage Check if Overpower Protection circuitry located directly behind the temperature controller inside the front tray has been activated Check if line switch is in t...

Страница 26: ...ose of this material and its container to a hazardous of special waste collection point Country State or local laws may impose additional regulatory requirements regarding disposal Dispose in accordan...

Страница 27: ...from the main instrument it is now easy to access the inside of the bath jar for further cleaning 16 With the top assembly resting on its back it is now possible to clean the heating coils stirrer bl...

Страница 28: ...low Blow Fuse 0 25A 5x20 mm 278 003 001 Slow Blow Fuse 3 15A 5x20mm 278 020 004 Time Delay Fuse 20A 600VAC 278 102 003 Fast Acting Fuse 0 5A 2AG 275 103 044 Temperature Controller 100 240V with RS 232...

Страница 29: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 25 9 Wiring Diagrams 9 1 Unit Wiring...

Страница 30: ...t for Amp 3 3 Brown 9 9 Blue Y3 V White 10 10 Blue Black X6 Output for Amp1 White 11 11 Blue White X7 Output for Amp 2 White 12 12 Blue Red X10 Output for Amp 3 4 Brown 13 13 White Y4 V White 14 14 Wh...

Страница 31: ...f the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or replac...

Страница 32: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 28 Notes...

Страница 33: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 29 Notes...

Страница 34: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 30 Notes...

Отзывы: