KV5000 Instrument & Software
Operation and Instruction Manual
KV5000-Manual
-
12-
Cannon®-Fenske Routine Viscometers
The Cannon
®
-Fenske Routine viscometer is a
rugged and inexpensive viscometer that works
well if the sample is transparent or translucent.
For kinematic viscosity of transparent liquids
up to 20,000cSt.
Requires a sample of approximately 7mL.
Use with K23780-CF Optical Detection
Assembly on the KV5000 viscosity bath.
Cannon®-Fenske Opaque Reverse Flow
Viscometers
The reverse flow viscometers are designed for
testing opaque liquids. These viscometers wet the
timing section of the viscometer capillary only
during the actual measurement and must be
cleaned, dried and refilled before a repeat
measurement can be made. By contrast, other
viscometer types commonly used to measure
transparent liquids allow the sample to be
repeatedly drawn up into the capillary, permitting
duplicate measurements.
For measurement of transparent and dark
liquids having kinematic viscosities of up to
20,000cSt
Requires a sample of approx 12mL.
Can be used for viscosities of asphalts by
ASTM D2170 method.
Use with K23780-RF Optical Detection
Assembly on the KV5000 viscosity bath.
Catalog No.
Size
Approximate
Constant,
cSt/s
Kinematic
Viscosity Range,
cSt
378-025-C02-OS
25
0.002
0.4 to 2
378-050-C02-OS
50
0.004
0.8 to 4
378-075-C02-OS
75
0.008
1.6 to 8
378-100-C02-OS 100
0.015
3 to 15
378-150-C02-OS 150
0.035
7 to 35
378-200-C02-OS 200
0.1
20 to 100
378-300-C02-OS 300
0.25
50 to 250
378-350-C02-OS 350
0.5
100 to 500
378-400-C02-OS 400
1.2
240 to 1,200
378-450-C02-OS 450
2.5
500 to 2,500
378-500-C02-OS 500
8
1,600 to 8,000
378-600-C02-OS 600
20
4,000 to 20,000
378-650-C02-OS 650
45
9,000 to 45,000
378-700-C02-OS 700
100
20,000 to 100,000
Ubbelohde Viscometers
Ubbelohde viscometers measure transparent
liquids, and unlike the Cannon
®
-Fenske Routine
viscometers, they maintain the same viscometer
constant at all temperatures. This is advantageous
when samples are to be measured at different
temperatures.
Suspended-level type viscometers are for
transparent liquids of up to 100,000cSt
Requires a sample volume of approx 11mL.
Use with K23780-UB Optical Detection
Assembly on the KV5000 viscosity bath.
Catalog No.
Size
Approx.
Constant,
cSt/s
Kinematic
Viscosity Range,
cSt
378-000-C03-OS
0
0.001
0.3 to 1
378-00C-C03-OS 0C
0.003
0.6 to 3
378-00B-C03-OS 0B
0.005
1 to 5
378-001-C03-OS
1
0.01
2 to 10
378-01C-C03-OS 1C
0.03
6 to 30
378-01B-C03-OS 1B
0.05
10 to 50
378-002-C03-OS
2
0.1
20 to 100
378-02C-C03-OS 2C
0.3
60 to 300
378-02B-C03-OS 2B
0.5
100 to 500
378-003-C03-OS
3
1
200 to 1,000
378-03C-C03-OS 3C
3
600 to 3,000
378-03B-C03-OS 3B
5
1,000 to 5,000
378-004-C03-OS
4
10
2,000 to 10,000
378-04C-C03-OS 4C
30
6,000 to 30,000
378-04B-C03-OS 4B
50
10,000 to 50,000
378-005-C03-OS
5
100
20,000 to
100,000
Catalog No.
Size
Approximate
Constant,
cSt/s
Kinematic
Viscosity Range,
cSt
378-025-C01-OS
25
0.002
0.5 to 2
378-050-C01-OS
50
0.004
0.8 to 4
378-075-C01-OS
75
0.008
1.6 to 8
378-100-C01-OS 100
0.015
3 to 15
378-150-C01-OS 150
0.035
7 to 35
378-200-C01-OS 200
0.1
20 to 100
378-300-C01-OS 300
0.25
50 to 250
378-350-C01-OS 350
0.5
100 to 500
378-400-C01-OS 400
1.2
240 to 1,200
378-450-C01-OS 450
2.5
500 to 2,500
378-500-C01-OS 500
8
1,600 to 8,000
378-600-C01-OS 600
20
4,000 to 20,000
378-650-C01-OS 650
45
9,000 to 45,000
378-700-C01-OS 700
100
20,000 to 100,000
Содержание KV5000
Страница 2: ......
Страница 4: ......
Страница 5: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 1...
Страница 6: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 2...
Страница 29: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 25 9 Wiring Diagrams 9 1 Unit Wiring...
Страница 32: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 28 Notes...
Страница 33: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 29 Notes...
Страница 34: ...KV5000 Instrument Software Operation and Instruction Manual KV5000 Manual 30 Notes...