5-2
WATER DISPENSER SWITCH
Refer to page 4-5 for the procedure for ac-
cessing the water dispenser switch.
1. Unplug refrigerator or disconnect power.
2. Disconnect the wires from the switch ter-
minals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the
dispenser switch terminals. The meter
should indicate an open circuit (infinite).
5. Press the actuator button on the switch,
and the meter should indicate a closed
circuit (0
Ω
).
Refer to page 4-9 for the procedure for access-
ing the flipper mullion.
1. Unplug refrigerator or disconnect power.
2. Disconnect the mullion connector from
the wiring harness.
3. Set the ohmmeter to the R x 1K scale.
4. Touch the ohmmeter test leads to the
mullion connector pins. The meter should
indicate between 1350 and 1500 Ω.
FLIPPER MULLION
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Dispenser
Switch
Mullion
Connector