5-4
COMPRESSOR
Refer to page 4-21 for the procedure for ac-
cessing the compressor.
1. Unplug refrigerator or disconnect power.
2. Remove the overload relay and motor start
capacitor from the compressor terminals.
3. Set the ohmmeter to the R x 1 scale.
4.
To test the compressor,
touch the ohm-
meter test leads to the indicated compres-
sor pins. The meter should indicate as fol-
lows:
a) Run (R) to common (C) = 3.3 Ω.
b) Start (S) to common (C) = 4.3 Ω.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
R
S
C
Compressor
Pinouts
Overload
Relay
Motor Start
Capacitor
Overload Relay &
Motor Start Cap
5.
To test the motor start capacitor,
set
the ohmmeter to the 10K scale. Touch
the ohmmeter test leads to the capaci-
tor terminals. The meter should indicate
several ohms, and then gradually return
to infinity.