4-17
REMOVING THE DUAL WATER VALVE
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug refrigerator or disconnect power.
2. Turn off the water supply to the refrigera-
tor.
3. Pull the refrigerator away from the wall so
that you can access the rear of the unit.
4. Disconnect the water line from its fitting.
5. Remove the four hex-head screws from
the water valve access cover, but do not
remove the cover at this time.
Water Valve Access Cover
Cover Screw
(1 of 4)
Water Line Fitting
Water Line
Fitting Retainer
Fitting Bracket
6. Squeeze the sides of the water line fit-
ting retainer and slide the retainer off its
bracket.
Slide Fitting
Off Retainer
7. Slide the water line fitting off the retainer.