94
PFX2512_CE
D
Reference Data
PFX2512 pattern charge/discharge
The data acquired under the following conditions.
System requirements
Measuring conditions
Pattern current waveform (measured by the current probe)
Setting conditions
The rising and falling waveforms of the pattern current (measured by the
current probe)
Setting conditions
Charge/discharge system controller
PFX2512
Power supply
PWR800L
Electronic load
PLZ1004W
The DUT (battery)
Use a 14 mm
2
cable with a length of 5 m to connect to a 25.9 V,
40 Ah Li-ion battery module.
Current probe
3274 (HIOKI)
Oscilloscope
TDS3032 (Tektronix)
2 values CC pattern charge/discharge
Step 1
CHG: 50 A 500 ms
Step 2
DISCHG: 50 A 500 ms
50 A
(CHG)
-50 A
(DISCH)
0 A
2 values CC pattern charge/discharge
Step 1
CHG: 50 A 500 ms
Step 2
DISCHG: 50 A 500 ms
50 A
(CHG)
-50 A
(DISCH)
0 A