
PFX2512_CE
35
Using BPChecker3000 to Control the PFX2512
2
In
st
al
la
ti
on
a
n
d P
re
p
ar
a
ti
o
n
Connecting PFX2512s through a switching hub (when using multiple
PFX2512s)
If you will use multiple PFX2512s, use LAN cables to connect them to the PC through a switching
hub.
■
Recommended switching hubs
Configuring PC settings (IP address)
You have to set the IP address and subnet mask on the PC that you are using to values that match
this product's IP address range. If the PC's IP address and subnet mask are not set correctly, you will
not be able to connect to the PFX2512.
In the factory default settings, a value in the range of 192.168.1.101 to 192.168.1.107 (the value
varies depending on the channel number setting) is assigned to the PFX2512 IP address.
1
On Windows XP, on the taskbar, click Start, Control Panel, and then Network
Connections.
On Windows 7, on the taskbar, click Start, Control Panel, and then View
network status and tasks under Network and Internet.
2
Click the Local Area Connection property.
3
On Windows XP, select the Internet Protocol (TCP/IP) check box, and then click
Properties.
On Windows 7, select the Internet Protocol Version 4 (TCP/IPv4) check box,
and then click Properties.
4
Click Use the following IP address.
5
Enter the IP address and subnet mask.
If you want to connect to a PFX2512 that has the IP address in the factory default
settings, set the IP address to 192.168.1.10 and the subnet mask to 255.255.255.0.
Model
Manufacturer
Number of
ports
Note
LSW3-TX-5NP/ WH
BUFFALO INC.
5
Internal power supply type
Can be mounted on a surface with magnets
ETX2-SH16N
I-O DATA DEVICE, INC.
16
Internal power supply type; metal case
Can be mounted on a 19-inch rack
TP
-
BUS
( PFX2121
)
DC POWER SUPPLY
AC INPUT
90-250V 50-60Hz
60VA MAX
KIKUSUI ELECTRONICS CORP.
MADE IN JAPAN
EXT CONT
AWG 24
STRIP
-
GAUGE
10mm
DC PS
1
2
3
SENSING
S1
+
S
MAX60V
-
S
+
T
-
T
FG
60V
50A
6
4
35
2
11
0
8
79
+
-
+
-
+
-
DC ELECTR
ONIC LO
AD
DC EL
DUT
SH DET
RESV
84
21
NC
TERMN
OFF
1
0
LA
N
RX
LINK
OP01
-
PFX
TERM
+
-
+
-
+
-
+
-
1234
THERMO
COUPLE
+
-
+
-
+
-
+
-
1
FG
234
FG
TERM
MAX20V
V
OLT
A
G
E
SENSING
To the
switching hub
To the LAN connector
PC
Switching hub
LAN cable
LAN cable
PFX2512
Содержание PFX2515
Страница 10: ...10 PFX2512_CE This page is intentionally blank ...
Страница 11: ...General Description This chapter describes the outline of product the connectable equipments and the options ...
Страница 58: ...58 PFX2512_CE This page is intentionally blank ...
Страница 59: ...Specification This chapter contains the PFX2512 specifications and outline drawings ...
Страница 86: ...86 PFX2512_CE This page is intentionally blank ...
Страница 100: ...100 PFX2512_CE This page is intentionally blank ...
Страница 103: ......