PFX2512_CE
83
Volt / Thermometer Unit OP02-PFX Specifications
5
Vo
lt
/
T
h
e
rm
o
m
e
te
r U
n
it
(
O
p
ti
o
n
)
Pattern charge/discharge feature and I-V characteristic charge/
discharge feature
Cell measurement function
Pattern
Pattern constant current
charge/ discharge
CC Pattern
Cutoff condition
Cell voltage (Cell Max Voltage and Cell Min Voltage)
Cell temperature (Cell Max Temp)
Cell unbalance (Cell Unbalance)
*1
*1.
The maximum and minimum cell voltages are calculated for the cells in the object under
measurement, and charging finishes when the difference between these two values exceeds the set
value.
Pattern constant power
charge/ discharge
CP Pattern
Cutoff condition
Cell voltage (Cell Max Voltage and Cell Min Voltage)
Cell temperature (Cell Max Temp)
Cell unbalance (Cell Unbalance) *1
I - V characteristics charge/
discharge
I -V Pattern
Cutoff condition
Cell voltage (Cell Max Voltage and Cell Min Voltage)
Cell temperature (Cell Max Temp)
Cell unbalance (Cell Unbalance) *1
Static
Cell voltage
Average current of the every 100 ms (Cell Voltage)
Cell temperature
Temperature measurement function using a thermocouple as a temperature
sensing element, updated every second (Cell Temperature)
Содержание PFX2515
Страница 10: ...10 PFX2512_CE This page is intentionally blank ...
Страница 11: ...General Description This chapter describes the outline of product the connectable equipments and the options ...
Страница 58: ...58 PFX2512_CE This page is intentionally blank ...
Страница 59: ...Specification This chapter contains the PFX2512 specifications and outline drawings ...
Страница 86: ...86 PFX2512_CE This page is intentionally blank ...
Страница 100: ...100 PFX2512_CE This page is intentionally blank ...
Страница 103: ......