:SBUS<n> Commands
25
Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
713
:SBUS<n>:NRZ:TRIGger
Command Syntax
:SBUS<n>:NRZ:TRIGger <mode>
<mode> ::= {SOF | VALue}
The :SBUS<n>:NRZ:TRIGger command specifies the trigger mode:
• SOF (Start Of Frame) — triggers at the start of a NRZ frame, before the header
field.
• VALue — triggers on the specified bit values (see
:SBUS<n>:NRZ:TRIGger:PATTern:VALue:WIDTh and
:SBUS<n>:NRZ:TRIGger:PATTern:VALue:DATA), up to 128 bits, after the
specified number of starting bits.
Note that the trigger value is always for bits as they arrive (that is, MSB first).
When the decode bit order (see :SBUS<n>:NRZ:BITorder) is MSBFirst, the
decoded value bit order matches the trigger value bit order.
When the serial decode bit order is LSBFirst, the decoded value bit order is
opposite of the trigger value bit order.
Query Syntax
:SBUS<n>:NRZ:TRIGger?
The :SBUS<n>:NRZ:TRIGger? query returns returns the trigger mode setting.
Return Format
<mode><NL>
<mode> ::= {SOF | VAL}
See Also
•
":SBUS<n>:NRZ:TRIGger:PATTern:VALue:DATA"
•
Содержание P9241
Страница 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Страница 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Страница 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Страница 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Страница 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Страница 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Страница 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Страница 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Страница 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Страница 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Страница 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Страница 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Страница 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Страница 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Страница 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Страница 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Страница 596: ...596 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 25 SBUS n Commands SBUS n A429 SOURce on page 588...
Страница 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Страница 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Страница 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Страница 1204: ...1204 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 37 More About Oscilloscope Commands...
Страница 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...